UPM Institutional Repository

Bioelectrical impedance analysis derived-phase angle as a pragmatic tool to detect protein energy wasting among multi-ethnic hemodialysis patients


Citation

Lim, Cordelia Kheng May and Lim, Jun Hao and Ibrahim, Imliya and Chan, Yoke Mun and Zakaria, Nor Fadhlina and Yahya, Rosnawati and Mat Daud, Zulfitri 'Azuan (2021) Bioelectrical impedance analysis derived-phase angle as a pragmatic tool to detect protein energy wasting among multi-ethnic hemodialysis patients. Diagnostics, 11 (10). art. no. 1745. pp. 1-15. ISSN 2075-4418

Abstract

Protein-energy wasting (PEW) is a devastating metabolic derangement that leads to increased morbidity and mortality in hemodialysis (HD) patients. This study aimed to determine the diagnostic test accuracy of bioelectrical impedance analysis derived-phase angle (PhA) in detecting PEW among HD patients. This was a multi-centre, cross-sectional study conducted amongst 152 multi-ethnic HD patients in Klang Valley, Malaysia. PEW was assessed using the International Society of Renal Nutrition and Metabolism criteria as the reference method. PhA was measured using a multi-frequency bioelectrical impedance spectroscopy at 50 kHz. Multiple and logistic regressions were used to determine factors associated with PhA and PEW diagnosis, respectively. A receiver operating characteristics curve analysis was used to establish the gender-specific PhA cut-offs to detect PEW. PEW existed in 21.1% of the HD patients. PhA was found as an independent predictor of PEW (adjOR = 0.308, p = 0.001), with acceptable to excellent discriminative performance (adjAUCmale = 0.809; adjAUCfemale = 0.719). Male patients had higher PhA cut-off compared to female patients (4.26° vs. 3.30°). We concluded that PhA is a valid and pragmatic biomarker to detect PEW in multi-ethnic Malaysian HD patients and a gender-specific cut-off is necessary, attributed to the gender differences in body composition.


Download File

Full text not available from this repository.
Official URL or Download Paper: https://www.mdpi.com/2075-4418/11/10/1745

Additional Metadata

Item Type: Article
Divisions: Faculty of Medicine and Health Science
DOI Number: https://doi.org/10.3390/diagnostics11101745
Publisher: Multidisciplinary Digital Publishing Institute
Keywords: Phase angle; Bioelectrical impedance; Body composition; Protein energy wasting; Hemodialysis
Depositing User: Ms. Nuraida Ibrahim
Date Deposited: 13 Feb 2023 07:47
Last Modified: 13 Feb 2023 07:47
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.3390/diagnostics11101745
URI: http://psasir.upm.edu.my/id/eprint/96225
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item