Citation
Abstract
Determination is made of glow curves attributes of Ge-doped silica fibres fabricated from Ge-doped preforms. In particular interest is in Ge-doped cylindrical (Ge-CF) and Ge-doped flat (Ge-FF). The fabrications are irradiated using various ionizing radiation sources types, protons (150 MeV, 210 MeV), 6 and 10 MV photons, 6 MeV electrons, and 60Co gammas (mean energy 1.25 MeV), all at a constant dose of 5 Gy. The fibres have been fabricated using the MCVD technique, notably with a Ge-CF having a larger core compared to the commercial cylindrical fibres (CF). Using WinGCF software the glow curves have been deconvolved, revealing five contributory glow peaks, evaluation being made of three kinetic parameters: maximum temperature (Tmax), activation energy (Ea) and peak integral (PI). Ge-CF Ea and PI values are found to be greater than those for Ge-FF. Moreover, for Ge-CF, the activation energy for electromagnetic irradiation (gamma photons) achieves a maximum reading at peak number 3 while its PI is found to be the least. The PI for photon irradiation is shown to be greater than that for electron and proton irradiation. For Ge-FF, Ea again achieves its greatest value at peak 3, the PI being maximum at peak 2 and least at peak 3. Particle irradiations are more greatly associated with deeper trapping levels. Additionally, the overall conclusion is that Ge-CF offers superior TL yield to that of Ge-FF. One-way analysis of variance (ANOVA) for the individual peaks shows there to be significant differences in terms of PI and Ea, p < 0.05 for all types of radiation, but weakly significant in terms of Tmax for both types of fibres (p < 0.05), mostly for proton and photon irradiation.
Download File
Full text not available from this repository.
Official URL or Download Paper: https://www.sciencedirect.com/science/article/pii/...
|
Additional Metadata
Item Type: | Article |
---|---|
Divisions: | Faculty of Medicine and Health Science |
DOI Number: | https://doi.org/10.1016/j.radphyschem.2020.108981 |
Publisher: | Elsevier |
Keywords: | Glow curve deconvolution; Ge-doped fabricated fibres; Kinetic parameters |
Depositing User: | Ms. Nuraida Ibrahim |
Date Deposited: | 05 Apr 2023 04:30 |
Last Modified: | 05 Apr 2023 04:30 |
Altmetrics: | http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.1016/j.radphyschem.2020.108981 |
URI: | http://psasir.upm.edu.my/id/eprint/95723 |
Statistic Details: | View Download Statistic |
Actions (login required)
View Item |