UPM Institutional Repository

Effect of miscentering and low-dose protocols on contrast resolution in computed tomography head examination


Citation

Said Rahmat, Said Mohd Shaffiq and Abdul Karim, Muhammad Khalis and Che Isa, Iza Nurzawani and Abd Rahman, Mohd Amiruddin and Mohd Noor, Noramaliza and Ng, Kwan Hoong (2020) Effect of miscentering and low-dose protocols on contrast resolution in computed tomography head examination. Computers in Biology and Medicine, 123. art. no. 103840. pp. 1-10. ISSN 0010-4825; ESSN: 1879-0534

Abstract

Background: Unoptimized protocols, including a miscentered position, might affect the outcome of diagnostic in CT examinations. In this study, we investigate the effects of miscentering position during CT head examination on the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Method: We simulate the CT head examination using a water phantom with a standard protocol (120 kVp/180 mAs) and a low dose protocol (100 kVp/142 mAs). The table height was adjusted to simulate miscentering by 5 cm from the isocenter, where the height was miscentered superiorly (MCS) at 109, 114, 119, and 124 cm, and miscentered inferiorly (MCI) at 99, 94, 89, and 84 cm. Seven circular regions of interest were used, with one drawn at the center, four at the peripheral area of the phantom, and two at the background area of the image. Results: For the standard protocol, the mean CNR decreased uniformly as table height increased and significantly differed (p < 0.05) at +20 cm for MCS (435.70 ± 9.39) and −20 cm for MCI (438.91 ± 10.94) from the isocenter. Similarly, significant reductions (p < 0.05) were also noted for SNR for MCS (at +20 cm) and MCI (at −20 cm). For the low dose protocol, both CNR and SNR were significantly reduced (p < 0.05) at table heights of +20 and −20 cm from the isocenter. Conclusion: Miscentering is proven to significantly affect the image quality in both low and standard dose protocols for head CT procedure. This study implies that accurate patient centering is one of the approaches that can improve CT optimization practice.


Download File

[img] Text (Abstract)
ABSTRACT.pdf

Download (65kB)

Additional Metadata

Item Type: Article
Divisions: Faculty of Medicine and Health Science
Faculty of Science
DOI Number: https://doi.org/10.1016/j.compbiomed.2020.103840
Publisher: Elsevier
Keywords: CT head; Miscentered position; Image quality; SNRCNR
Depositing User: Ms. Nuraida Ibrahim
Date Deposited: 21 Dec 2021 07:30
Last Modified: 21 Dec 2021 07:30
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.1016/j.compbiomed.2020.103840
URI: http://psasir.upm.edu.my/id/eprint/88618
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item