UPM Institutional Repository

Screening of electrocoagulation process parameters for treated palm oil mill effluent using minimun-runs resolution IV design


Citation

Mujeli, Mustapha and Hussain, Siti Aslina and Ismail, Mohd Halim Shah and Awang Biak, Dayang Radiah and Jami, Mohammed Saedi (2018) Screening of electrocoagulation process parameters for treated palm oil mill effluent using minimun-runs resolution IV design. International Journal of Environmental Science and Technology, 16 (8). pp. 811-820. ISSN 1735-1472; ESSN: 1735-2630

Abstract

The present study aimed at the screening of parameters for electrocoagulation treatment of treated palm oil mill effluent using minimum-runs resolution IV design. The responses examined include: chemical oxygen demand removal (%), total suspended solids removal (%) and turbidity reduction (%), and the varied dependent factors comprise: electrical current density (mA/cm²), time (min), pH, electrolyte concentration (g/L), stirring speed (rpm), electrode spacing (mm) and electrode configuration (monopolar or dipolar). The statistical results revealed that the current density has a significant influence on the treatment performance at two-level interactions with pH, electrode spacing and electrode concentration and at three-level correlations with time and pH. Thus, the most important factors affecting the removal efficiency of the organic compounds were found to be pH, time, electrode spacing, electrolyte concentration and electrode configuration at a P value less than 0.05, respectively, in the descending order of significance. Therefore, the optimized electrocoagulation process could be reached with current density equal to 5 mA/cm², electrolysis time of 5 min, electrode spacing of 5 mm and using monopolar electrode configuration. This combination provided the maximum ability of the process for chemical oxygen demand (68.84%), total suspended solids (93.27%) and turbidity reduction (92.88%) predictions, with the corresponding experimental values of 69.27, 97.59 and 96.91%, respectively.


Download File

[img] Text
Screening of electrocoagulation process parameters for treated palm oil mill effluent using minimun-runs resolution IV design.pdf

Download (64kB)

Additional Metadata

Item Type: Article
Divisions: Faculty of Engineering
DOI Number: https://doi.org/10.1007/s13762-018-1708-9
Publisher: Springer
Keywords: Electrocoagulation; Minimum-runs resolution IV design; Reclamation; Treated palm oil mill effluent
Depositing User: Mr. Sazali Mohamad
Date Deposited: 13 Aug 2021 00:55
Last Modified: 13 Aug 2021 00:55
Altmetrics: http://www.altmetrics.com/details.php?domain=pasir.upm.edu.my&doi=10.1007/s13762-018-1708-9
URI: http://psasir.upm.edu.my/id/eprint/82067
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item