Laccase electrochemical biosensor based on graphene-gold/chitosan nanocomposite film for bisphenol a detection


Citation

Fartas, Fuzi Mohamed and Abdullah, Jaafar and Yusof, Nor Azah and Sulaiman, Yusran and Saiman, Mohd Izham and Mat Zaid, Mohd Hazani (2019) Laccase electrochemical biosensor based on graphene-gold/chitosan nanocomposite film for bisphenol a detection. Current Analytical Chemistry, 16 (5). pp. 570-579. ISSN 1573-4110; ESSN: 1875-6727

Abstract

Background: Bisphenol A (BPA) is considered one of the most common chemicals that could cause environmental endocrine disrupting. Therefore, there is an increasing demand for simple, rapid and sensitive methods for BPA detection that result from BPA leaching into foods and beverages from storage containers. Herein, a simple laccase electrochemical biosensor was developed for the determination of BPA based on Screen-Printed Carbon Electrode (SPCE) modified graphenegold/ chitosan. The synergic effect of graphene-gold/chitosan nanocomposite as electrode modifier greatly facilitates electron-transfer processes between the electrolyte and laccase enzyme, thus leads to a remarkably improved sensitivity for bisphenol A detection. Methods: In this study, laccase enzyme is immobilized onto the Screen-Printed Carbon Electrode (SPCE) modified Graphene-Decorated Gold Nanoparticles (Gr-AuNPs) with Chitosan (Chit). The surface structure of nanocomposite was studied using different techniques including Field Emission Scanning Microscopy (FESEM), TRANSMISSION Electron Microscopy (TEM), Raman spectroscopy and Energy Dispersive X-ray (EDX). Meanwhile, the electrochemical performances of the modified electrodes were studied using Cyclic Voltammetry (CV) and Differential Pulse Voltammetry (DPV). Result: The developed laccase biosensor offered excellent analytical performance for the detection of BPA with a sensitivity of 0.271 μA/μM and Limit of Detection (LOD) of 0.023 μM, respectively. Moreover, the constructed biosensor showed good reproducibility, selectivity and stability towards BPA. The sensor has been used to detect BPA in a different type of commercial plastic products as a real sample and satisfactory result was obtained when compared with the HPLC method. Conclusion: The proposed electrochemical laccase biosensor exhibits good result which is considered as a promising candidate for a simple, rapid and sensitive method especially in the resource- limited condition.


Download File

[img] Text
Laccase electrochemical biosensor based on graphene-gold.pdf

Download (65kB)
Official URL or Download Paper: https://www.eurekaselect.com/169075/article

Additional Metadata

Item Type: Article
Divisions: Faculty of Science
Institute of Advanced Technology
DOI Number: https://doi.org/10.2174/1573411015666190117114804
Publisher: Bentham Science Publishers
Keywords: Bisphenol A; Electrochemical biosensor; Graphene-gold nanocomposite; Laccase; Screen-Printed Carbon Electrode (SPCE); Synergic effect
Depositing User: Ms. Nida Hidayati Ghazali
Date Deposited: 17 Jun 2021 00:26
Last Modified: 17 Jun 2021 00:26
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=https://doi.org/10.2174/1573411015666190117114804
URI: http://psasir.upm.edu.my/id/eprint/81192
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item