UPM Institutional Repository

Industrial radiotracer application in flow rate measurement and flowmeter calibration using ⁹⁹mTc and ¹⁹⁸Au nanoparticles radioisotope


Citation

Mohd Yunus, Mohd Amirul Syafiq and Hussain, Siti Aslina and Sipaun, Susan Maria (2019) Industrial radiotracer application in flow rate measurement and flowmeter calibration using ⁹⁹mTc and ¹⁹⁸Au nanoparticles radioisotope. Applied Radiation and Isotopes, 143. pp. 24-28. ISSN 0969-8043; ESSN: 1872-9800

Abstract

The flow rate or fluid velocity measurement is important to maintain fluid flow quality performance in the systems. This study focuses on determination of volumetric flow rate measurement and to calibrate the conventional flowmeter using industrial radiotracer approach in quadrilateral gas-liquid bubble column reactor. In this work, two different radioisotopes which emit γ-ray have been chosen as radioactive tracer which is 99mTc produced from 99Mo/99mTc radioisotope generator and 198Au nanoparticle form neutron activation at research nuclear reactor TRIGA Mark II. Both radioisotopes representing liquid and solid tracer purposely designed for tracing liquid flow. The peak to peak radiotracer method known as pulse velocity method was applied to determine the volumetric flow rate. The radiation signals were monitored using 4 unit NaI scintillation detectors located at 4 different points nearby the inlet and outlet of the quadrilateral bubble column reactor process stream. The water volume inside the bubble column reactor was fixed at 0.04 m3 and liquid flow rates in this reactor were specified on installed flowmeter at different reference value which is 4 lpm, 8 lpm, and 12 lpm, respectively. The experimental result shows very good linearity and repeatability by following the theoretical equations with less uncertainty in volumetric flow rate measurement. The obtained results also validated the effectiveness of the proposed method for the installed flowmeter calibration efficiency.


Download File

[img] Text
Industrial radiotracer application in flow rate measurement and flowmeter calibration using 99mTc and 198Au nanoparticles radioisotope.pdf
Restricted to Repository staff only

Download (493kB)

Additional Metadata

Item Type: Article
Divisions: Faculty of Engineering
DOI Number: https://doi.org/10.1016/j.apradiso.2018.10.008
Publisher: Elsevier
Keywords: Industrial radiotracer; Gold nanoparticle tracer; Flowrate measurement; Closed conduit; Scintillation detector; Bubble column
Depositing User: Azhar Abdul Rahman
Date Deposited: 19 Oct 2020 17:09
Last Modified: 19 Oct 2020 17:09
Altmetrics: http://altmetrics.com-details.php?domain=psair.upm.edu.my&doi=10.1016/j.apradiso.2018.10.008
URI: http://psasir.upm.edu.my/id/eprint/80247
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item