UPM Institutional Repository

Evaluation of the analytical performance of a portable ion-selective electrode meter for measuring whole-blood, plasma, milk, abomasal-fluid, and urine sodium concentrations in cattle


Citation

A. A., Megahed and Hiew, M. and Grünberg, W. and Trefz, F. M. and Constable, P. D. (2019) Evaluation of the analytical performance of a portable ion-selective electrode meter for measuring whole-blood, plasma, milk, abomasal-fluid, and urine sodium concentrations in cattle. Journal of Dairy Science, 102 (8). pp. 7435-7444. ISSN 0022-0302; ESSN: 1525-3198

Abstract

A portable ion-selective electrode (ISE) meter (LAQUAtwin B-722; Horiba Instruments Inc., Irvine, CA) is available for measuring the sodium ion concentration ([Na]) in biological fluids. The objective of this study was to characterize the analytical performance of the ISE meter in measuring [Na] in whole-blood, plasma, milk, abomasal fluid, and urine samples from cattle. Method comparison studies were performed using whole-blood and plasma samples from 106 sick calves and 11 sick cows admitted to a veterinary teaching hospital, 80 milk and 206 urine samples from 16 lactating Holstein-Friesian cows with experimentally induced free water, electrolyte, and acid-base imbalances, and 67 abomasal fluid samples from 7 healthy male Holstein-Friesian calves fed fresh milk with or without an oral electrolyte solution. Deming regression and Bland-Altman plots were used to determine the accuracy of the meter against reference methods. The meter used in direct mode on undiluted samples measured whole-blood [Na] 9.7 mmol/L (7.3%) lower than a direct ISE reference method and plasma [Na] 16.7 mmol/L (12.7%) lower than an indirect ISE reference method. The meter run in direct mode measured milk [Na] 3.1 mmol/L lower and abomasal fluid [Na] 9.0% lower than indirect ISE reference methods. The meter run in indirect mode on diluted samples accurately measured urine [Na] compared with an indirect ISE reference method. We conclude that, after adjustment for the bias determined from Bland-Altman plots, the LAQUAtwin ISE meter provides a clinically useful and low-cost cow-side instrument for measuring [Na] in whole blood, plasma, milk, and abomasal fluid.


Download File

Full text not available from this repository.

Additional Metadata

Item Type: Article
Divisions: Faculty of Veterinary Medicine
DOI Number: https://doi.org/10.3168/jds.2018-16198
Publisher: Elsevier
Keywords: Hyponatremia; Hypernatremia; Point-of-care; Cattle
Depositing User: Nurul Ainie Mokhtar
Date Deposited: 04 Nov 2022 09:36
Last Modified: 04 Nov 2022 09:36
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.3168/jds.2018-16198
URI: http://psasir.upm.edu.my/id/eprint/79772
Statistic Details: View Download Statistic

Actions (login required)