UPM Institutional Repository

Dosimetric response of fabricated Ge-doped optical fibres in computed tomography RQT beam quality x-ray beams


Citation

Mohd Rais, Nur Nadiah and Bradley, David A. and Hashim, Asmaliza and Mohd Isa, Nur Ayuni and Osman, Noor Diyana and Itam @ Ismail, Iskasymar and Abu Hassan, Hasyma and Mohd Noor, Noramaliza (2019) Dosimetric response of fabricated Ge-doped optical fibres in computed tomography RQT beam quality x-ray beams. Journal of Radiological Protection, 39 (3). pp. 8-18. ISSN 0952-4746; ESSN: 1361-6498

Abstract

Novel germanium (Ge)-doped silica glass fibres tailor-made in Malaysia are fast gaining recognition as potential media for thermoluminescence (TL) dosimetry, with active research ongoing into exploitation of their various beneficial characteristics. Investigation is made herein of the capability of these media for use in diagnostic imaging dosimetry, specifically at the radiation dose levels typically obtained in conduct of Computed Tomography (CT). As a first step within such efforts, there is need to investigate the performance of the fibres using tightly defined spectra, use being made of a Philips constant potential industrial x-ray facility, Model MG165, located at the Malaysian Nuclear Agency Secondary Standards Dosimetry Lab (SSDL). Standard radiation beam qualities (termed RQT) have been established for CT, in accord with IEC 61267: 2003 and IAEA Technical Reports Series No. 457: 2007. A calibrated ionisation chamber has also been utilised, forming a component part of the SSDL equipment. The fabricated fibres used in this study are 2.3 mol% flat fibre (FF) of dimensions 643 × 356 μm2 and 2.3 mol% cylindrical fibre (CF) of 481 μm diameter, while the commercial fibre used is 4 mol% with core diameter of 50 μm. The dopant concentrations are nominal preform values. The fibres have been irradiated to doses of 20, 30 and 40 milligray (mGy) for each of the beam qualities RQT 8, RQT 9 and RQT 10. For x-rays generated at constant potential values from 100 to 150 kV, a discernible energy-dependent response is seen, comparisons being made with that of lithium fluoride (LiF) thermoluminescence dosimeters (TLD-100). TL yield versus dose has also been investigated for x-ray doses from 2 to 40 mGy, all exhibiting linearity. Compared to TLD-100, greater sensitivity is observed for the fibres.


Download File

[img] Text
Dosimetric response of fabricated .pdf

Download (67kB)
Official URL or Download Paper: https://pubmed.ncbi.nlm.nih.gov/31018196/

Additional Metadata

Item Type: Article
Divisions: Faculty of Medicine and Health Science
DOI Number: https://doi.org/10.1088/1361-6498/ab1c16
Publisher: IOP Publishing
Keywords: Ge-doped; Computed tomography; RQT; Beam quality; X-ray beams
Depositing User: Nurul Ainie Mokhtar
Date Deposited: 08 Apr 2021 00:45
Last Modified: 08 Apr 2021 00:45
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.1088/1361-6498/ab1c16
URI: http://psasir.upm.edu.my/id/eprint/79445
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item