Citation
Zhang, Si Wei
(2009)
Experimental Investigation of a Vacuum Cooling System.
Masters thesis, Universiti Putra Malaysia.
Abstract
The quality and safety of food are currently concerned by the world of population
now. Usually, the surface temperature of horticultural crops, such as vegetables and
fruits, remain high after harvesting. With the strong respiration, they continually
release heat, so that the contented water keeps on evaporating and losing.
Consequently, the deterioration will happen and get worse during this period.
Therefore, several pre-cooling methods come up in succession, such as
hydro-cooling, room cooling, forced air cooling and others. Apart from these
methods, vacuum cooling is also an effective and a rapid evaporative pre-cooling
method for porous and moisture foods to meet special cooling requirements. The
basic principle of vacuum cooling consists of removing the latent heat of a product,
which implies a rapid decrease in the temperature. Vacuum cooling can be used as
an effective method for pre-cooling to prolong their shelf life or by preventing the
influence of heat field. In previous research on this subject matter, the vacuum
cooling method has been used in relation to food products. However, the cooling
times from these research still has the challenge to improve. This could be due to the
disposition of system equipment, the vacuum pump selection or the matching between pumping speed and chamber volume. None of the studies conducted so far
has referred to vacuum pump selection and the matching between pumping speed
and chamber volume. A proper research investigation on this selection and matching
could benefit the vacuum cooling method to improve upon the cooling times.
In this study, the selection of vacuum pump and the matching between pumping
speed and chamber volume of vacuum cooling system are discussed and investigated
in detail. A product of vacuum cooling system was designed without vapour
condenser and operated by a single oil vacuum pump. Tests were carried out to
investigate the effect of different vacuum levels, pumping speeds and temperatures
on selected vegetables in the vacuum cooling process. Based on the discussion on
the pressure, pumping speeds and temperatures, the results indicate that the vacuum
cooling system can be operated without vapour condenser and by a single oil
vacuum pump. The results also show that porous products pre-cooling using this
method can be shortened in less than 4 min in this type of vacuum cooling system.
Download File
Additional Metadata
Actions (login required)
|
View Item |