Evaluating the effect of economizer on efficiency of the fire tube steam boiler


Citation

Lahijani, Seyed Ahmad Mahmoudi and Supeni, Eris Elianddy (2018) Evaluating the effect of economizer on efficiency of the fire tube steam boiler. Innovative Energy & Research, 7 (1). pp. 1-4. ISSN 2576-1463

Abstract

In this paper, the effects of using economizer on efficiency of examined fire tube steam boiler is presented. Based on the live tests, the performance indexes of two fire tube 3 passes wet back steam boilers with capacity of 3000 kg/h (one of them with economizer and another without economizer) measured. A MATLAB analysis with the comparison of different results is developed to evaluate the results produced by the live test. The indirect method is the applied method in this study, therefore various types of losses is measured. The results show the effect of using economizer for increase the feed water temperature and improving the efficiency of fire tube steam boiler.


Download File

[img] Text
Evaluating the effect of economizer on efficiency of the fire tube steam boiler.pdf

Download (5kB)

Additional Metadata

Item Type: Article
Divisions: Faculty of Engineering
DOI Number: https://doi.org/10.4172/2576-1463.1000193
Publisher: OMICS Publishing
Keywords: Fire tube boiler; Boiler efficiency; Economizer
Depositing User: Nurul Ainie Mokhtar
Date Deposited: 16 Nov 2020 04:41
Last Modified: 16 Nov 2020 04:41
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.4172/2576-1463.1000193