Mehrjou, Mohammad Rezazadeh and Mariun, Norman and Marhaban, Mohammad Hamiruce and Misron, Norhisam (2010) Fourier analysis of motor current for diagnosis of broken bars in squirrel-cage induction machines. In: 2010 IEEE Student Conference on Research and Development (SCOReD 2010), 13-14 Dec. 2010, Palm Garden Hotel, IOI Resort, Putrajaya, Malaysia. (pp. 475-478).

Abstract

Condition monitoring, signal processing and data analysis are the key parts of the induction machine (IM) fault detection scheme. Frequency analysis of the signal acquired through the condition monitoring is commonly applied for motor fault detection. This paper is intended to investigate the ability and effectiveness of Fourier analysis of motor current for broken rotor bar detection. Accordingly, the current signals at different amount of load were measured and analyzed for broken rotor bar diagnosis in a squirrel-cage induction machine.


Download File

[img]
Preview
Text (Abstract)
Fourier analysis of motor current for diagnosis of broken bars in squirrel-cage induction machines.pdf

Download (34kB) | Preview

Additional Metadata

Item Type: Conference or Workshop Item (Paper)
Divisions: Faculty of Engineering
DOI Number: https://doi.org/10.1109/SCORED.2010.5704057
Publisher: IEEE
Keywords: Squirrel-cage induction machine; Fault detection; Condition monitoring; Signal processing
Depositing User: Nabilah Mustapa
Date Deposited: 10 Jun 2019 03:33
Last Modified: 10 Jun 2019 03:33
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.1109/SCORED.2010.5704057
URI: http://psasir.upm.edu.my/id/eprint/68759
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item