UPM Institutional Repository

Reliability, technical error of measurements and validity of instruments for nutritional status assessment of adults in Malaysia


Citation

Appannah, Geeta and Haniff, Jamaiyah and Mohammad Nor, Noor Safiza and Wong, N. F. and Kee, Chee Cheong and Zainuddin, Ahmad Ali and Shahar, Suzana and Rasat, Rahmah and Khor, Geok Lin and Abd Talib, Ruzita and Chen, Won Sun and M., Rajaah and Yusoff, Ahmad Faudzi (2008) Reliability, technical error of measurements and validity of instruments for nutritional status assessment of adults in Malaysia. Malaysian Journal of Nutrition, 14 (2). S25-S26. ISSN 1394-035X

Abstract

The Third National Health & Morbidity Survey, Malaysia 2006 included nutritional status assessment of children. This study was to assess inter-and intra-examiner reliability, the technical error of measurement (TEM) and the validity of instruments for measuring weight, length and waist circumference. A convenience sample of 130 adults working in a selected office setting who fit the inclusion and exclusion criteria participated in the study. Two public health nurses, trained to follow a standard protocol, obtained the measurements. Weight was measured using Tanita digital weighing scale, 318, Japan (0.1 kg) and Seca Beam Scale, Germany (0.01 kg) weighing machines. Height was measured using Seca Bodymeter 206 Germany (0.1cm) and Stadiometer, Germany (0.1cm). Waist circumference was measured using Seca circumference tape, 206, Germany (0.1 cm). By comparison the inter-examiner reliability in descending order would be weight, height and lastly waist circumference. The intra-examiner reliability in descending order would be weight and height followed by waist circumference. Height measurement on average using test instrument reported that it was recording 0.4 cm higher than the reference instrument with upper limit and lower limit at 2.5 and 1.6 cm respectively. The technical error of measurement and coefficient of variation of weight and height for both inter-examiner and intra-examiner measurements are all within acceptable limit (below 5%). The findings of this study supports that weight, height and waist circumference measured in adults 30 years and above using Tanita digital weighing scale, 318, Japan (0.1 kg), Seca Bodymeter 206 Germany (0.1cm) and Seca circumference tape, 206, Germany (0.1 cm) are reliable and valid to be used in a community survey. Limiting the number of examiners especially for waist circumference measurements would yield higher degree of reliability and validity.


Download File

[img]
Preview
PDF (Abstract)
Reliability, techincal error.pdf

Download (85kB) | Preview

Additional Metadata

Item Type: Article
Divisions: Faculty of Medicine and Health Science
Publisher: Nutrition Society of Malaysia
Depositing User: Anas Yahaya
Date Deposited: 21 May 2010 03:42
Last Modified: 01 Dec 2015 08:34
URI: http://psasir.upm.edu.my/id/eprint/6844
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item