UPM Institutional Repository

Automatic artifact removal in EEG of normal and demented individuals using ICA-WT during working memory tasks


Citation

Al-Qazzaz, Noor Kamal and Mohd Ali, Sawal Hamid and Ahmad, Siti Anom and Islam, Mohd Shabiul and Escudero, Javier (2017) Automatic artifact removal in EEG of normal and demented individuals using ICA-WT during working memory tasks. Sensors, 17 (6). pp. 1-25. ISSN 1424-8220

Abstract

Characterizing dementia is a global challenge in supporting personalized health care. The electroencephalogram (EEG) is a promising tool to support the diagnosis and evaluation of abnormalities in the human brain. The EEG sensors record the brain activity directly with excellent time resolution. In this study, EEG sensor with 19 electrodes were used to test the background activities of the brains of five vascular dementia (VaD), 15 stroke-related patients with mild cognitive impairment (MCI), and 15 healthy subjects during a working memory (WM) task. The objective of this study is twofold. First, it aims to enhance the recorded EEG signals using a novel technique that combines automatic independent component analysis (AICA) and wavelet transform (WT), that is, the AICA-WT technique; second, it aims to extract and investigate the spectral features that characterize the post-stroke dementia patients compared to the control subjects. The proposed AICA-WT technique is a four-stage approach. In the first stage, the independent components (ICs) were estimated. In the second stage, three-step artifact identification metrics were applied to detect the artifactual components. The components identified as artifacts were marked as critical and denoised through DWT in the third stage. In the fourth stage, the corrected ICs were reconstructed to obtain artifact-free EEG signals. The performance of the proposed AICA-WT technique was compared with those of two other techniques based on AICA and WT denoising methods using cross-correlation X C o r r and peak signal to noise ratio ( P S N R ) (ANOVA, p ˂ 0.05). The AICA-WT technique exhibited the best artifact removal performance. The assumption that there would be a deceleration of EEG dominant frequencies in VaD and MCI patients compared with control subjects was assessed with AICA-WT (ANOVA, p ˂ 0.05). Therefore, this study may provide information on post-stroke dementia particularly VaD and stroke-related MCI patients through spectral analysis of EEG background activities that can help to provide useful diagnostic indexes by using EEG signal processing.


Download File

[img]
Preview
Text
Automatic artifact removal in EEG of normal and demented individuals using ICA-WT during working memory tasks.pdf

Download (3MB) | Preview

Additional Metadata

Item Type: Article
Divisions: Faculty of Engineering
Malaysian Research Institute on Ageing
DOI Number: https://doi.org/10.3390/s17061326
Publisher: Multidisciplinary Digital Publishing Institute
Keywords: Electroencephalography; Independent component analysis; Mild cognitive impairment; Spectral analysis; Vascular dementia; Wavelet
Depositing User: Ms. Nida Hidayati Ghazali
Date Deposited: 14 May 2019 03:25
Last Modified: 14 May 2019 03:25
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.3390/s17061326
URI: http://psasir.upm.edu.my/id/eprint/60978
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item