UPM Institutional Repository

Thermal sensations and comfort investigations in transient conditions in tropical office


Citation

Dahlan, Nur Dalilah and Gital, Yakubu Yau (2015) Thermal sensations and comfort investigations in transient conditions in tropical office. Applied Ergonomics, 54. pp. 169-176. ISSN 0003-6870; ESSN: 1872-9126

Abstract

The study was done to identify affective and sensory responses observed as a result of hysteresis effects in transient thermal conditions consisting of warm-neutral and neutral - warm performed in a quasi-experiment setting. Air-conditioned building interiors in hot-humid areas have resulted in thermal discomfort and health risks for people moving into and out of buildings. Reports have shown that the instantaneous change in air temperature can cause abrupt thermoregulation responses. Thermal sensation vote (TSV) and thermal comfort vote (TCV) assessments as a consequence of moving through spaces with distinct thermal conditions were conducted in an existing single-story office in a hot-humid microclimate, maintained at an air temperature 24 °C (± 0.5), relative humidity 51% (± 7), air velocity 0.5 m/s (± 0.5), and mean radiant temperature (MRT) 26.6 °C (± 1.2). The measured office is connected to a veranda that showed the following semi-outdoor temperatures: air temperature 35 °C (± 2.1), relative humidity 43% (± 7), air velocity 0.4 m/s (± 0.4), and MRT 36.4 °C (± 2.9). Subjective assessments from 36 college-aged participants consisting of thermal sensations, preferences and comfort votes were correlated against a steady state predicted mean vote (PMV) model. Local skin temperatures on the forehead and dorsal left hand were included to observe physiological responses due to thermal transition. TSV for veranda-office transition showed that no significant means difference with TSV office-veranda transition were found. However, TCV collected from warm-neutral (-0.24, ± 1.2) and neutral-warm (-0.72, ± 1.3) conditions revealed statistically significant mean differences (p < 0.05). Sensory and affective responses as a consequence of thermal transition after travel from warm-neutral-warm conditions did not replicate the hysteresis effects of brief, slightly cool, thermal sensations found in previous laboratory experiments. These findings also indicate that PMV is an acceptable alternative to predict thermal sensation immediately after a down-step thermal transition (≤ 1 min exposure duration) for people living in a hot-humid climate country.


Download File

[img]
Preview
PDF (Abstract)
Thermal sensations and comfort investigations in transient conditions in tropical office.pdf

Download (107kB) | Preview
Official URL or Download Paper: http://www.elsevier.com/locate/issn/00036870

Additional Metadata

Item Type: Article
Divisions: Faculty of Design and Architecture
DOI Number: https://doi.org/10.1016/j.apergo.2015.12.008
Publisher: Pergamon Press
Keywords: Semi-outdoor and indoor; Tropical microclimate; Thermal transition; Thermal perception; Skin temperatures; Thermal preference; Thermal sensation vote; PMV; Hysteresis effect
Depositing User: Ms. Nida Hidayati Ghazali
Date Deposited: 06 Feb 2018 06:08
Last Modified: 06 Feb 2018 06:08
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.1016/j.apergo.2015.12.008