Natural ventilation provisions in terraced-house designs in hot-humid climates: case of Putrajaya, Malaysia


Citation

Idowu, Ibiyeye Aminat and Ja'afar, Mohamad Fakri Zaky and Shari, Zalina (2015) Natural ventilation provisions in terraced-house designs in hot-humid climates: case of Putrajaya, Malaysia. Pertanika Journal of Social Sciences & Humanities, 23 (4). pp. 885-904. ISSN 0128-7702; ESSN: 2231-8534

Abstract

Due to the high risk of global warming from the increased level of energy consumption, energy sustainability is increasingly practised around the world especially in the residential sector. Attempts to save energy in hot-humid climates however, are mainly through improved mechanical cooling. Consequently, residential buildings are built to be air tight and they are provided with insufficient opening areas for natural ventilation which in turn, results in the deterioration of indoor air quality (IAQ). Previous studies on IAQ with respect to ventilation rates are mostly on indoor concentrations of contaminants and various diseases associated with them. Detailed studies on openings and their impact on delivered ventilation rates are still limited, particularly in hot-humid climates. This study investigates natural ventilation provisions in different house design types in Putrajaya, Malaysia with respect to the Uniform Building By-Law (UBBL) governing them. Five terrace house design types were selected, of which two were found to be non-compliant with UBBL 10% window area requirement. Simulations were conducted using the Integrated Environment Solution (IES〈VE〉) software and the results reveal that house types complying with the UBBL requirements exhibit higher ventilation rates and a longer duration of leaving windows open is found to improve ventilation rates. This paper informs regulatory stakeholders, designers and clients of the residential building sector of the impact of open designs on occupants' health and the importance of UBBL compliance and enforcement. This study further emphasises the need for occupants to increase the duration of leaving windows open and to embrace night ventilation as a means of improving natural ventilation in their homes.


Download File

[img]
Preview
PDF
08 JSSH Vol 23 (4) Dec 2015_pg885-904 (JSSH 1139-2014).pdf

Download (2MB) | Preview

Additional Metadata

Item Type: Article
Divisions: Faculty of Design and Architecture
Publisher: Universiti Putra Malaysia Press
Keywords: Hot-humid climate; Indoor air quality; Natural ventilation; Residential buildings; Terraced houses; Uniform Building By-Law; Ventilation rates; Window openings
Depositing User: Nabilah Mustapa
Date Deposited: 28 Jan 2016 04:53
Last Modified: 23 Feb 2016 03:29
URI: http://psasir.upm.edu.my/id/eprint/41759