UPM Institutional Repository

Development of tailor-made silica fibres for TL dosimetry


Citation

Bradley, David Andrew and Abdul Sani, Siti Fairus and Alalawi, Amani I. and Jafari, Shakardokht M. and Mohd Noor, Noramaliza and Abdul Rashid, Hairul Azhar and Mahdiraji, Ghafour Amouzad and Tamchek, Nizam and Ghosh, Sudipta Kumar and Paul, Mukul Chandra and Alzimami, Khalid S. and Nisbet, Andrew and Maah, Mohd Jamil (2014) Development of tailor-made silica fibres for TL dosimetry. Radiation Physics and Chemistry, 104. pp. 3-9. ISSN 0969-806X; ESSN: 1879-0895

Abstract

The Ge dopant in commercially available silica optical fibres gives rise to appreciable thermoluminscence (TL), weight-for-weight offering sensitivity to MV X-rays several times that of the LiF dosimeter TLD100. The response of these fibres to UV radiation, X-rays, electrons, protons, neutrons and alpha particles, with doses from a fraction of 1 Gy up to 10 kGy, have stimulated further investigation of the magnitude of the TL signal for intrinsic and doped SiO2 fibres. We represent a consortium effort between Malaysian partners and the University of Surrey, aimed at production of silica fibres with specific TL dosimetry applications, utilizing modified chemical vapour deposition (MCVD) doped silica–glass production and fibre-pulling facilities. The work is informed by defect and dopant concentration and various production dependences including pulling parameters such as temperature, speed and tension; the fibres also provide for spatial resolutions down to <10 µm, confronting many limitations faced in use of conventional (TL) dosimetry. Early results are shown for high spatial resolution (~0.1 mm) single-core Ge-doped TL sensors, suited to radiotherapy applications. Preliminary results are also shown for undoped flat optical fibres of mm dimensions and Ge-B doped flat optical fibres of sub-mm dimensions, with potential for measurement of doses in medical diagnostic applications.


Download File

[img]
Preview
PDF (Abstract)
Development of tailor-made silica fibres for TL dosimetry.pdf

Download (48kB) | Preview

Additional Metadata

Item Type: Article
Divisions: Faculty of Medicine and Health Science
Faculty of Science
DOI Number: https://doi.org/10.1016/j.radphyschem.2014.03.042
Publisher: Elsevier
Keywords: Silica fibres; Defects; Thermoluminescence; Dosimetry
Depositing User: Nabilah Mustapa
Date Deposited: 01 Dec 2015 06:19
Last Modified: 01 Dec 2015 06:19
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.1016/j.radphyschem.2014.03.042
URI: http://psasir.upm.edu.my/id/eprint/37084
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item