Bahraminasab, Marjan and Sahari, Barkawi and Edwards, Kevin L. and Farahmand, Farzam and Tang, Sai Hong and Arumugam, Manohar and Jahan, Ali (2014) Multi-objective design optimization of functionally graded material for the femoral component of a total knee replacement. Materials and Design, 53 . pp. 159-173. ISSN 0264-1275; ESSN: 1873-4197

Abstract

The optimal design of complex systems in engineering requires pursuing rigorous mathematical modeling of the system’s behavior as a function of a set of design variables to achieve goal-oriented design. Despite the success of current knee implants, the limited life span remains the main concern of this complex system. The mismatch between the properties of engineered biomaterials and those of biological materials leads to insufficient bonding with bone, stress shielding effects and wear problems (i.e. aseptic loosening). The use of a functionally graded material (FGM) for the femoral component of knee implants is attractive because the properties can be designed to vary in a certain pattern to meet the desired requirements at different regions in the knee joint system, thereby decreasing loosening problem. However, matching the properties does not necessarily guarantee the best functionality of the knee implant and there is a need for developing the optimal design of an FGM femoral component that is longer lasting. In this study, therefore, a multi-objective design optimization of a FGM femoral component is carried out using finite element analysis (FEA) and response surface methodology (RSM). The results of using optimized FGM are then compared with the use of standard Co–Cr alloy in a femoral component knee implant to demonstrate relative performance.


Download File

Full text not available from this repository.

Additional Metadata

Item Type: Article
Divisions: Faculty of Engineering
Faculty of Medicine and Health Science
Institute of Advanced Technology
DOI Number: https://doi.org/10.1016/j.matdes.2013.06.050
Publisher: Elsevier
Keywords: Material selection; Material design; Multi-objective decision making; Knee prosthesis; Aseptic loosening; Design of experiments
Depositing User: Nurul Ainie Mokhtar
Date Deposited: 16 Dec 2015 04:02
Last Modified: 16 Dec 2015 04:02
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.1016/j.matdes.2013.06.050
URI: http://psasir.upm.edu.my/id/eprint/34607
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item