UPM Institutional Repository

Method development and validation of nitrofuran metabolites in shrimp by liquid chromatographic mass spectrometric system


Citation

Hossain, M. B. and Ahmed, S. and Rahman, M. F. and Yunus, Kamaruzzaman and Chowdhury, Ahmed Jalal Khan and Sarker, S. M. Nurul Amin Harmuj Ali (2013) Method development and validation of nitrofuran metabolites in shrimp by liquid chromatographic mass spectrometric system. Journal of Biological Sciences, 13 (1). pp. 33-37. ISSN 1727-3048; ESSN: 1812-5719

Abstract

Liquid Chromatographic Mass Spectrometric System (LCMSMS) method was developed and validated in shrimp matrix for determination of nitrofuran metabolites in the laboratory of fish inspection and quality control, Department of Fisheries, Matshya Bhaban, Dhaka, Bangladesh. This confirmatory method was used for testing samples for residues of the metabolites of the following nitrofuran compounds, furazolidone (3-amino-2-oxazolidinone, AOZ); furaltadone (5-methyl-morpholino-3-amino-2-oxazolidinone, AMOZ); nitrofurazone (semicarbazide, SEM) and nitrofurantoin (1-aminohydantoin, AHD) in shrimp. The data were generated (3 levels and seven replicates per level) on each of three days for shrimp. The mean recoveries from the tissues were 88-110%, the decision limits (CCα) were 0.12-0.23 ppb and the detection capabilities (CCα) 0.21-0.38 ppb. CCα and CCβ were calculated using the procedure set out in ISO Guide 11843. Nevertheless, CCα value for all nitrofuran metabolites can be investigated and meet the specified easily met the specified EU MRPL of 1 μg kg-1 ranged from 0.12-0.23 μg kg-1 and suitable for routine quality control operations.


Download File

[img]
Preview
PDF (Abstract)
Method development and validation of nitrofuran metabolites in shrimp by liquid chromatographic mass spectrometric system.pdf

Download (50kB) | Preview
Official URL or Download Paper: http://scialert.net/abstract/?doi=jbs.2013.33.37

Additional Metadata

Item Type: Article
Divisions: Faculty of Agriculture
DOI Number: https://doi.org/10.3923/jbs.2013.33.37
Publisher: Asian Network for Scientific Information
Keywords: Decision limit; Detection capability; Method validation; Nitrofuran; Shrimp
Depositing User: Nurul Ainie Mokhtar
Date Deposited: 13 Jul 2016 02:24
Last Modified: 13 Jul 2016 02:24
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.3923/jbs.2013.33.37
URI: http://psasir.upm.edu.my/id/eprint/29349
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item