UPM Institutional Repository

3D experimental detection and discrimination of malignant and benign breast tumor using NN-based UWB imaging system


Citation

Alshehri, Saleh Ali and Khatun, Sabira and Jantan, Adznan and Raja Abdullah, Raja Syamsul Azmir and Mahmud, Rozi and Awang, Zaiki (2011) 3D experimental detection and discrimination of malignant and benign breast tumor using NN-based UWB imaging system. Progress In Electromagnetics Research, 116. pp. 221-237. ISSN 1070-4698; ESSN: 1559-8985

Abstract

This paper presents both simulation and experimental study to detect and locate breast tumors along with their classification as malignant and/or benign in three dimensional (3D) breast model. The contrast between the dielectric properties of these two tumor types is the main key. These dielectric properties are mainly controlled by the water and blood content of tumors. For simulation, electromagnetic simulator software is used. The experiment is conducted using commercial Ultrawide-Band (UWB) transceivers, Neural Network (NN) based Pattern Recognition (PR) software for imaging and homogenous breast phantom. The 3D homogeneous breast phantom and tumors are fabricated using pure petroleum jelly and a mixture of wheat flour and water respectively. The simulation and experimental setups are performed by transmitting the UWB signals from one side of the breast model and receiving from opposite side diagonally. Using discrete cosine transform (DCT) of received signals, we have trained and tested the developed experimental Neural Network model. In 3D breast model, the achieved detection accuracy of tumor existence is around 100%, while the locating accuracy in terms of (x, y, z) position of a tumor within the breast reached approximately 89.2% and 86.6% in simulation and experimental works respectively. For classification, the permittivity and conductivity detection accuracy are 98.0% and 99.1% in simulation, and 98.6% and 99.5% in experimental works respectively. Tumor detection and type specification 3D may lead to successful clinical implementation followed by saving of precious human lives in the near future.


Download File

[img]
Preview
PDF (Abstract)
23515.pdf

Download (38kB) | Preview
Official URL or Download Paper: http://www.jpier.org/PIER/pier.php?paper=11022601

Additional Metadata

Item Type: Article
Divisions: Faculty of Engineering
Faculty of Medicine and Health Science
DOI Number: https://doi.org/10.2528/PIER11022601
Publisher: EMW Publishing
Keywords: Breast phantom; Breast tumor; Conductivity detection; Detection accuracy
Depositing User: Nur Farahin Ramli
Date Deposited: 23 Dec 2013 04:24
Last Modified: 29 Sep 2016 03:50
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.2528/PIER11022601
URI: http://psasir.upm.edu.my/id/eprint/23515
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item