Grounding systems is a fundamental part in an electrical power engineering system. It is important for ensuring the safety of occupants, to protect electrical equipment from damage, minimize the risk of electrical hazards and maintain a stable system during both normal and fault conditions. Hence, a grounding system must provide a path for fault currents to safely dissipate into Earth while preventing electrical shock hazard, and reduce and limit the damage to any electrical equipment connected to it. However, traditional grounding systems may not always be able to provide the required level of conductivity, especially in high soil resistivity sites or in applications where high fault currents are anticipated. Resistivity of the surrounding soil is one of the parameters that can be easily manipulated for an efficient grounding system to be made available as it is influenced by factors such as geographical location, moisture content, temperature, and soil composition. In regions with poor natural soil conductivity or environments characterized by seasonal fluctuations in resistivity, the deployment of natural enhancement material is merged as a critical solution. In this work, three sites located around Universiti Putra Malaysia Serdang Campus, Selangor, MALAYSIA were tested for its soil resistivity. This is meant for grounding system installations with new natural enhancement material mixtures in the vicinity of vertical ground conductors. Site 2 with high resistivity and most homogeneous soil would be chosen to test the grounding system installations, while Site 1 with the lowest soil resistivity would be installed with Reference grounding system as comparison purposes. Note that a Reference grounding system is installed without any natural enhancement material mixture in the vicinity of the vertical ground conductor.


Download File

[img] Text
121562.pdf - Published Version
Restricted to Repository staff only

Download (462kB)
Official URL or Download Paper: https://ieeexplore.ieee.org/document/10892493/

Additional Metadata

Item Type: Conference or Workshop Item (Oral/Paper)
Divisions: Faculty of Engineering
DOI Number: https://doi.org/10.1109/iSPEC59716.2024.10892493
Publisher: Institute of Electrical and Electronics Engineers
Keywords: Grounding system; Soil resistivity; Natural enhancement materials; Wenner method
Depositing User: Mr. Mohamad Syahrul Nizam Md Ishak
Date Deposited: 06 Nov 2025 03:25
Last Modified: 06 Nov 2025 03:25
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.1109/iSPEC59716.2024.10892493
URI: http://psasir.upm.edu.my/id/eprint/121562
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item