UPM Institutional Repository

Optimizing time-of-flight of PET/CT image quality via penalty β value in Bayesian penalized likelihood reconstruction algorithm


Citation

Murat, H. and Zulkifli, M.A.A. and Said, M.A. and Awang Kechik, M. and Tahir, D. and Abdul Karim, M.K. (2025) Optimizing time-of-flight of PET/CT image quality via penalty β value in Bayesian penalized likelihood reconstruction algorithm. Radiography, 31 (1). pp. 343-349. ISSN 1078-8174; eISSN: 1532-2831

Abstract

Introduction: Optimizing the image quality of Positron Emission Tomography/Computed Tomography (PET/CT) systems is crucial for effective monitoring, diagnosis, and treatment planning in oncology. This study evaluates the impact of time-of-flight (TOF) on PET/CT performance, focusing on varying penalty β values within Q. Clear reconstruction algorithm. Methods: The study measured signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) using the Discovery MI PET/CT scanner and NEMA IQ phantom filled with the radiotracer fluorodeoxyglucose (18F-FDG). PET/CT scans were performed with and without TOF using β values of 100, 500, 1000, 1500, 2000, and 3000. Pixel intensity values were measured using ImageJ software, and SNR and CNR were calculated. Results: Results indicated that increasing β values improved SNR and CNR for both non-TOF and TOF images. At a β value of 100, SNR and CNR increased across all sphere sizes (10 mm, 13 mm, 17 mm, 22 mm, 28 mm, 37 mm) when comparing non-TOF and TOF images. However, β values of 500 or higher led to decreased SNR and CNR, particularly in larger spheres (22 mm, 28 mm, 37 mm), when TOF was utilized. Conclusion: These findings underscore the importance of optimizing β values and employing TOF reconstruction in PET/CT scans to achieve the highest possible image quality. Implications for practice: In clinical practice, practitioners should adjust β values in accordance with routine protocols, considering the size of the target region and the use of TOF reconstruction.


Download File

[img] Text
119178.pdf - Published Version
Restricted to Repository staff only

Download (1MB)

Additional Metadata

Item Type: Article
Divisions: Faculty of Science
DOI Number: https://doi.org/10.1016/j.radi.2024.12.011
Publisher: W.B. Saunders Ltd
Keywords: Bayesian penalized likelihood; Image quality; Image reconstruction; Positron emission tomography; Time-of-flight; β value
Depositing User: Mohamad Jefri Mohamed Fauzi
Date Deposited: 07 Aug 2025 03:34
Last Modified: 07 Aug 2025 03:34
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.1016/j.radi.2024.12.011
URI: http://psasir.upm.edu.my/id/eprint/119178
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item