UPM Institutional Repository

Voltammetric-based immunosensing of Newcastle disease virus on polyethylene glycol-containing self-assembled monolayer modified gold electrode


Citation

Abd Muain, Mohamad Farid and Amir Hamzah, Amir Syahir and Chia, Suet Lin and Yusoff, Khatijah and Lim, Hong Ngee and Shinya, Ikeno and Ahmad Tajudin, Asilah (2025) Voltammetric-based immunosensing of Newcastle disease virus on polyethylene glycol-containing self-assembled monolayer modified gold electrode. Analytical Biochemistry, 697. art. no. 115700. pp. 1-8. ISSN 0003-2697; eISSN: 1096-0309

Abstract

A voltammetric immunosensor for the detection of Newcastle disease virus (NDV) has been developed by employing polyclonal antibody targeting NDV (anti-NDV) as a bioreceptor. Anti-NDV was immobilized on polyethylene glycol (PEG)-containing self-assembled monolayer (SAM) which was activated with N-(3-dimethylaminopropyl)-N′-ethylcarbodiimidehydrochloride (EDC) and N-hydroxy succinimide (NHS) coupling on screen-printed gold electrode (SPGE). The introduction of PEG-containing SAM on the SPGE allowed the bioreceptor to covalently bound to the electrode surface whilst still providing a hydrophilic layer on the electrode which is important to greatly reduce non-specific bindings. The bioreceptor functionalized electrode was then allowed to be incubated with NDV-spiked samples. The electrode surface modification with PEG-containing SAM, immobilization of anti-NDV as bioreceptor, up to the detection of NDV were characterized electrochemically through differential pulse voltammetry (DPV) analysis in [Fe(CN)6]3- as the redox probe. Decrement of anodic current peak (Ipa) of [Fe(CN)6]3- was seen as the concentration of NDV increased from 0.156 to 20 HA μL−1 with the limit of detection (LoD) of 1.50 HA μL−1 at 3σ m−1. The detection of NDV in HA μL−1 unit in this study would ease interlaboratory interpretation as it was the same unit used in hemagglutination (HA) assay of conventional NDV diagnosis. The specificity of anti-NDV used as bioreceptor towards NDV was confirmed through western blot analysis, whilst the selectivity of the bioreceptor-functionalized electrode has been tested with allantoic fluid as the negative control in which no apparent changes of anodic peak (Ipa) has been seen. This simple, fast, and less laborious electrochemical detection method could become an alternative to the conventional method for NDV detection.


Download File

[img] Text
119133.pdf - Published Version
Restricted to Repository staff only

Download (2MB)

Additional Metadata

Item Type: Article
Divisions: Faculty of Biotechnology and Biomolecular Sciences
Faculty of Science
Institute of Bioscience
DOI Number: https://doi.org/10.1016/j.ab.2024.115700
Publisher: Academic Press Inc.
Keywords: Electrochemical immunosensor; Newcastle disease virus; Polyclonal antibody; Polyethylene glycol alkanethiol
Depositing User: Mohamad Jefri Mohamed Fauzi
Date Deposited: 06 Aug 2025 07:45
Last Modified: 06 Aug 2025 07:45
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.1016/j.ab.2024.115700
URI: http://psasir.upm.edu.my/id/eprint/119133
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item