UPM Institutional Repository

The impact of wind catchers on thermal comfort and indoor air quality: An analysis of subtropical climate for summer and winter


Citation

Khalid, Asma and Dahlan, Nur Dalilah and Abas, Mohd Firdaus and Ahmad, Kamarul Arifin and Shahidan, Mohd Fairuz (2025) The impact of wind catchers on thermal comfort and indoor air quality: An analysis of subtropical climate for summer and winter. Indoor and Built Environment, 34 (4). art. no. 4. pp. 838-867. ISSN 1420-326X; eISSN: 1423-0070

Abstract

Employees spend 8 h of the day with a minimum of 40 h a week in offices. The office design, furniture and ventilation modes cause high energy consumption, pollutants and sick building syndrome amongst employees. Based on ASHRAE standards and WHO guidelines, the study evaluated offices for the temperature, humidity, PM2.5, CO2 and employees’ subjective assessment. The offices met humidity standards except for the Punjab Civil Secretariat (PCS) (61.9%, ± 0.1) and the Directorate of Public Instruction (54.1%, ± 0.3) in the summer and winter respectively. The concentrations of CO2 in offices were unhealthy for both seasons except the PCS (697.3 ppm, ± 9.2) and Punjab Skill Development Authority (838.9 ppm, ± 13.3). The mean PM2.5 concentration for offices was unhealthy during summer (28.4–53.7 μg/m3) and hazardous in winter (178–233.7 μg/m3). The one-way ANOVA of employees’ subjective assessment showed that the results were significant (p < 0.05) for indoor air quality, thermal comfort satisfaction, preference, health effect, filtration and wind catcher preference, for two seasons and within ventilation modes. The familiarity with wind catcher designs was insignificant (p > 0.05) but employees preferred their modern applications. The comfort indexes showed that the Governor House (PMV -0.04, PPD 5%) met the thermal comfort standards during winter.


Download File

[img] Text
117685.pdf - Accepted Version

Download (2MB)

Additional Metadata

Item Type: Article
Divisions: Faculty of Design and Architecture
Faculty of Engineering
DOI Number: https://doi.org/10.1177/1420326X251323242
Publisher: SAGE Publications
Keywords: Indoor air quality; Standards; Sub-tropical climate; Thermal comfort; Wind catcher; Wind chimney
Depositing User: Scopus
Date Deposited: 11 Jun 2025 04:25
Last Modified: 11 Jun 2025 04:25
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.1177/1420326X251323242
URI: http://psasir.upm.edu.my/id/eprint/117685
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item