UPM Institutional Repository

Green synthesized CaO decorated ternary CaO/g-C3N4/PVA nanocomposite modified glassy carbon electrode for enhanced electrochemical detection of caffeic acid


Citation

Karthika, Annamalai and Sudhakar, C. and Karuppasamy, Periyakaruppan and Tamilselvi, Baluchamy and Meena, Subramaniam and Anantharaju, Kurupalya Shivram and Tan, K. B. and Murthy, H. C. Ananda (2024) Green synthesized CaO decorated ternary CaO/g-C3N4/PVA nanocomposite modified glassy carbon electrode for enhanced electrochemical detection of caffeic acid. Scientific Reports, 14 (1). art. no. 28714. ISSN 2045-2322; eISSN: 2045-2322

Abstract

A highly selective, sensitive caffeic acid (CA) detection based on calcium oxide nanoparticles (CaO NPs) derived from extract of Moringa oleifera leaves decorated graphitic carbon nitride covalently grafted poly vinyl alcohol (CaO/g-C3N4/PVA) nanocomposite modified glassy carbon electrode (GCE) was studied. A facile sonochemical method was adapted to synthesis nanomaterials and characterized by HR-TEM (High resolution transmission electron microscopy), FT-IR (Fourier transform infrared spectroscopy), XRD (X-ray diffraction), FE-SEM (Field emission scanning electron microscopy), EDX (Energy dispersive X-ray analysis), Mapping and BET (Brunauer-Emmett-Teller) analysis, and electrochemical techniques. The nanocomposite modified GCE exhibited an excellent catalytic performance to the oxidation of CA under optimized conditions owing to better electron transfer efficiency, conductivity and high surface area of the electrode material. The present electrochemical sensor showed high selectivity towards the determination of 10 µM CA in the presence of 100-fold higher concentrations of interferents. The modified CA sensor exhibited a wide sensing linear range from 0.01 µM to 70 µM and the detection limit (LOD) was found to be 0.0024 µM (S/N = 3) in 0.1 M phosphate buffer saline (PBS) as a supporting electrolyte at pH 7.0. The fabricated CA sensor provides an excellent stability, reproducibility and selectivity for the determination of CA. The modified CA sensor was applied to real blood plasma samples and obtained good recovery (97.6-100.1%) results. © The Author(s) 2024.


Download File

[img] Text
116189.pdf - Published Version
Available under License Creative Commons Attribution Non-commercial No Derivatives.

Download (2MB)

Additional Metadata

Item Type: Article
Divisions: Faculty of Science
DOI Number: https://doi.org/10.1038/s41598-024-80146-2
Publisher: Nature Research
Keywords: Amperometric study; Anticancer drug; Caffeic acid (CA); CaO/g-C<sub>3</sub>N<sub>4</sub>/PVA nanocomposite; Electrochemical Sensor; Plasma samples
Depositing User: Ms. Azian Edawati Zakaria
Date Deposited: 20 Mar 2025 04:22
Last Modified: 20 Mar 2025 04:22
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.1038/s41598-024-80146-2
URI: http://psasir.upm.edu.my/id/eprint/116189
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item