UPM Institutional Repository

An innovative air-cooling system for efficiency improvement of retrofitted rooftop photovoltaic module using cross-flow fan


Citation

Mustafa, Rozita and Mohd Radzi, Mohd Amran and Hizam, Hashim and Che Soh, Azura (2024) An innovative air-cooling system for efficiency improvement of retrofitted rooftop photovoltaic module using cross-flow fan. International Journal of Renewable Energy Development, 13 (2). pp. 223-234. ISSN 2252-4940

Abstract

This study presents an innovative air-cooling photovoltaic (PV) system using cross-flow fan with speed regulation to optimize performance of rooftop PV system in tropical climates like Malaysia. Air passed through the impeller enters perpendicularly to the motor shaft, deflected by the fan blades and evacuated, allowing the fan to operate at its most efficient operating point. The airflow provided within the rear of the PV modules and the roof surface blow out the trapped hot air. Changes in the PV module temperature (Tcell) are detected and the fan speed are adjusted accordingly to the PWM. This method was tested for 12 hours continuously from 7:00 am on the existing PV system at German Malaysian Institute (GMI) Bangi. The highest Tcell achieved 72.88 °C and 55.75°C without and with air-cooling system with average power 210.22 W and 246.67 W per peak sun factor (PSF) respectively. There was a 17.34% increase in average power with a 13.18% in average net output power and achieved 6.68% energy efficiency using the proposed cooling system. Tcell increases more swiftly and reaches higher temperatures in the absence of a cooling system, whereas Tcell increases more slowly and at lower temperatures when a cooling system is present. The projected system's power rating was 6.48 W, which is 2.6% per PV module, and it really attained 6.32 W, which is 2.53% per PV module, while total energy consumption by the fan was 51.89 Wh per day, which is only 3.89% per PV module. © The author(s). Published by CBIORE. This is an open access article under the CC BY-SA license.


Download File

[img] Text
112043.pdf - Published Version
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (996kB)

Additional Metadata

Item Type: Article
Divisions: Faculty of Engineering
DOI Number: https://doi.org/10.61435/ijred.2024.60068
Publisher: Diponegoro university Indonesia - Center of Biomass and Renewable Energy (CBIORE)
Keywords: Cooling technique; Cross-flow fan; Photovoltaic; Pv module temperature; Uniform air-cooling
Depositing User: Ms. Azian Edawati Zakaria
Date Deposited: 28 Oct 2024 04:04
Last Modified: 28 Oct 2024 04:04
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.61435/ijred.2024.60068
URI: http://psasir.upm.edu.my/id/eprint/112043
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item