UPM Institutional Repository

Real-time germanium-doped optical fibers for clinical computed tomography dosimetry


Citation

Sarhan, H.G. and Saini, S.M. and Bahari, N.M. and Bradley, D.A. and Zubair, H.T. and Basaif, A. and Oresegun, A.A. and Abdul Rashid, H.A. and M. Noor, N. (2023) Real-time germanium-doped optical fibers for clinical computed tomography dosimetry. Radiation Physics and Chemistry, 209 (110972). pp. 1-6. ISSN 0969-806X

Abstract

In studies focusing on the practice of clinical computed tomography (CT) a particular concern has been that of delivering unnecessary dose to patients and with it the added risk for radiation-induced cancers. For a CT system, present work has investigated the dosimetric characteristics of a Ge-doped optical fiber real-time dosimetry system (model LS-2000, Lumisyns), measuring beam quality, exposure linearity and exposure duration accuracy. For comparison, the study has used a RaySafe X2 test device (Unfors RaySafe) and a Black Piranha (RTI) QA meter. Irradiations were made using a Somatom Definition Flash dual-source 128-slice CT scanner (Siemens Healthcare). The LS-2000, RaySafe X2, and Black Piranha sensors were exposed to beams energized at accelerating potentials ranging from 80 to 140 kVp, with tube current-time products from 50 to 300 mA, and exposure durations from 750 to 2000 ms. Constant signal responses from the LS-2000 have been obtained, measured in respect of beam quality, exposure linearity, and time accuracy. In respect of accuracy of beam quality, the RaySafe X2 and Black Piranha maximum deviations were 1 and 5, respectively; the coefficients of linearity of RaySafe, Black Piranha and LS-2000 are 1, 0.4 and 1.4, respectively; the maximum deviation for the time accuracy test for the three sensors are 0.5, 2 and 1.3, respectively. Evaluation of the LS-2000 real-time dosimetry system with a Ge-doped optical fiber scintillator points to potential for its use in clinical CT dosimetry.


Download File

[img] Text
110442.pdf - Published Version
Restricted to Repository staff only
Available under License Creative Commons Attribution.

Download (3MB)

Additional Metadata

Item Type: Article
Divisions: Faculty of Medicine and Health Science
Hospital Pengajar UPM
DOI Number: https://doi.org/10.1016/j.radphyschem.2023.110972
Publisher: Elsevier BV
Keywords: Computed tomography; Fabricated ge-doped silica fiber; Ls-2000; Radioluminescence; Real-time optical fiber dosimetry; Good health and well-being
Depositing User: Ms. Nuraida Ibrahim
Date Deposited: 07 Oct 2024 02:54
Last Modified: 07 Oct 2024 02:54
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.1016/j.radphyschem.2023.110972
URI: http://psasir.upm.edu.my/id/eprint/110442
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item