UPM Institutional Repository

Thermal and degradation analysis of electrospun polyurethane prepared using radiation induced grafting


Citation

Ahmad Tarmizi, Zatil Izzah and Rasit Ali, Roshafima and Nasef, Mohamed Mahmoud and Mohamed Radzi, Afifah Mardhiah and Md Akim, Abdah and Eshak, Zolkapli and Md Noor, Sabariah and Shafie, Nur Fathin Amirah and Mohd Faizo, Syazwani (2023) Thermal and degradation analysis of electrospun polyurethane prepared using radiation induced grafting. Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 108 (2). 110 - 121. ISSN 2289-7879

Abstract

Polyurethane (PU) membranes was prepared using electrospinning followed by modification with 2-hydroxyethyl methacrylate (HEMA) by radiation-induced grafting (RIG) copolymerization method via electron beam. The lack of knowledge of polymer properties of PU-based membrane prepared using RIG method need for dedicated study. Thus, the effect of thermal stability, in vitro degradation, water uptake analysis, and surface morphology after 84 days’ incubation times toward grafted PU-g-poly(HEMA) membrane was evaluated for the first time using thermal gravimetric analysis (TGA), analysis of mass, percentage of water uptake and Scanning Electron Microscope (SEM), respectively. Based on the DTGA curves, the electrospun PU exhibits two-stage of deposition. After grafted with HEMA, the first stage of decomposition was shifted to the lower temperature, and the second stage of decomposition was shifted to a higher temperature. At 500 °C, PU grafted with HEMA leaves residue about 3.526 more elevated in value than original material of PU, which is 1.151. Degradation test showed that a higher percentage degree of grafting was lowering the percentage of weight loss. SEM images supported the morphology observation shows no noticeable changes such as cracked or eroded has occurred. In conclusion, electrospun PU grafted with HEMA was improved its thermal stability, stable in swelling properties and was found competent to degrade slowly in phosphate buffer saline (PBS). The results show that PU-g-poly(HEMA) exhibits better thermal stability than pure poly(HEMA) and the amorphous regions give the polymer toughness and could be up-and coming candidates for tissue engineering including artificial blood contracting medical devices.


Download File

Full text not available from this repository.

Additional Metadata

Item Type: Article
Divisions: Faculty of Medicine and Health Science
DOI Number: https://doi.org/10.37934/arfmts.108.2.110121
Publisher: Semarak Ilmu Publishing
Keywords: Electrospinning; Polyurethane; Radiation induced grafting copolymerization
Depositing User: Ms. Zaimah Saiful Yazan
Date Deposited: 04 Sep 2024 04:26
Last Modified: 04 Sep 2024 04:26
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.37934/arfmts.108.2.110121
URI: http://psasir.upm.edu.my/id/eprint/110128
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item