UPM Institutional Repository

A reliability study of isometric shoulder internal and external rotation strength in young badminton players using a hand-held dynamometry


Citation

Abdullah, Borhannudin and Samsudin, Shamsulariffin and Gasibat, Qais and Mohd Nasirudddin, Nasnoor Juzaily (2023) A reliability study of isometric shoulder internal and external rotation strength in young badminton players using a hand-held dynamometry. Journal of Physical Education and Sport, 23 (7). 1642 - 1649. ISSN 2247-8051; ESSN: 2247-806X

Abstract

Accurate measurement of internal rotation and external rotation (IR/ER) muscle strength is crucial for badminton players, coaches, and support staff to ensure appropriate training prescription and reduce the risk of injuries. Previous studies have highlighted the significance of measurement position and stabilisation in achieving reliable outcomes. This study aimed to assess the reliability of Hand-Held Dynamometry (HHD) in measuring shoulder IR/ER strength among young club badminton players using the Microfet 2„¢ dynamometer. Thirty young badminton players aged 17.4±1.8 years, with a body mass of 56.08±5.7 kg, participated in the study. Isometric strength tests (ISTs) for shoulder IR/ER were conducted using the Microfet 2„¢ dynamometer. To determine the reliability, the same strength tests were repeated two days apart for each participant. The results demonstrated high reliability for both IR (ICC = 0.92-0.91) and ER (ICC = 0.99“0.96) in both dominant and non-dominant shoulders. Additionally, the percentage of Smallest Real Difference (SRD) remained consistently below 20 for IR and below 12 for ER in both shoulders. The ER/IR ratio also showed good reliability (ICC = 0.83 and 0.82) for both dominant and non-dominant shoulders. The findings of this study indicate that HHD using the Microfet 2„¢ is a reliable tool for measuring shoulder IR/ER strength in young badminton players. The high reliability and low SRD percentages suggest that the device can yield consistent results, which is essential for accurate training prescription and injury prevention. The use of the Microfet 2„¢ dynamometer in measuring shoulder IR/ER strength among young badminton players is supported by the high reliability demonstrated in this study. Coaches, players, and support staff can confidently utilize this tool to optimize training programs and minimize the risk of injuries in this population.


Download File

Full text not available from this repository.
Official URL or Download Paper: https://www.efsupit.ro/index.php/archive?id=151

Additional Metadata

Item Type: Article
Divisions: Faculty of Educational Studies
DOI Number: https://doi.org/10.7752/jpes.2023.07201
Publisher: Editura Universitatea din Pitesti
Keywords: Handheld dynamometer; Muscle asymmetry; Shoulder movement; Reliability; Good health and well-being
Depositing User: Ms. Che Wa Zakaria
Date Deposited: 06 Aug 2024 06:44
Last Modified: 06 Aug 2024 06:44
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.7752/jpes.2023.07201
URI: http://psasir.upm.edu.my/id/eprint/106663
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item