UPM Institutional Repository

Estimating local diagnostic reference levels for mammography in Dubai


Citation

Abdulwahid Noor, Kaltham and Mohd Norsuddin, Norhashimah and Abdul Karim, Muhammad Khalis and Che Isa, Iza Nurzawani and Alshamsi, Wadha (2024) Estimating local diagnostic reference levels for mammography in Dubai. Diagnostics, 14 (1). art. no. 8. pp. 1-13. ISSN 2075-4418

Abstract

As the total volume of mammograms in Dubai is increasing consistently, it is crucial to focus on the process of dose optimization by determining dose reference levels for such sensitive radiographic examinations as mammography. This work aimed to determine local diagnostic reference levels (DRLs) for mammography procedures in Dubai at different ranges of breast thickness. A total of 2599 anonymized mammograms were randomly retrieved from a central dose survey database. Mammographic cases for screening women aged from 40 to 69 years were included, while cases of breast implants and breast thickness outside the range of 20–100 mm were excluded. Mean, median, and 75 percentiles were obtained for the mean glandular dose (MGD) distribution of each mammography projection for all compressed breast thickness (CBT) ranges. The local DRLs for mammography in Dubai were found to be between 0.80 mGy and 0.82 mGy for the craniocaudal (CC) projection and between 0.89 mGy and 0.971.8 mGy for the mediolateral oblique (MLO) projection. Local DRLs were proposed according to different breast thicknesses, starting from 20 to 100 mm. All groups of CBT showed a slight difference in MGD values, with higher values in MLO views rather than CC views. The local DRLs in this study were lower than some other Middle Eastern countries and lower than the standard reference levels reported by the International Atomic Energy Agency (IAEA) at 3 mGy/view.


Download File

Full text not available from this repository.
Official URL or Download Paper: https://www.mdpi.com/2075-4418/14/1/8

Additional Metadata

Item Type: Article
Divisions: Faculty of Science
DOI Number: https://doi.org/10.3390/diagnostics14010008
Publisher: MDPI AG
Keywords: Diagnostic reference level; Mammography; Mean glandular dose; Organ dose; Radiation dose optimization; Breast health; Healthcare practices; Breast composition; Dose survey data; Dose TQM system; Local DRLs; National DRLs; Radiology departments
Depositing User: Mr. Mohamad Syahrul Nizam Md Ishak
Date Deposited: 22 Mar 2024 01:35
Last Modified: 22 Mar 2024 01:35
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.3390/diagnostics14010008
URI: http://psasir.upm.edu.my/id/eprint/105864
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item