UPM Institutional Repository

Pre-induction cervical assessment using transvaginal ultrasound versus bishops cervical scoring as predictors of successful induction of labour in term pregnancies: a hospital-based comparative clinical trial


Citation

Abang Abdullah, Zainab Hananah and Chew, Kah Teik and V. Velayudham, V. Ramesh and Yahaya, Zainab and Mohd Jamil, Amilia Afzan and Abu, Muhammad Azrai and Abdul Ghani, Nur Azurah and Mohamed Ismail, Nor Azlin (2022) Pre-induction cervical assessment using transvaginal ultrasound versus bishops cervical scoring as predictors of successful induction of labour in term pregnancies: a hospital-based comparative clinical trial. PLoS ONE, 17 (1). art. no. e0262387. pp. 1-14. ISSN 1932-6203

Abstract

Objective To evaluate the association between transvaginal ultrasound scan of cervix and Bishop’s score in predicting successful induction of labour, cut-off points and patients’ tolerability and acceptance for both procedures. Design A comparative clinical trial. Setting A tertiary hospital in Selangor, Malaysia. Participants 294 women planned for elective induction of labour for various indications were included. All women had transvaginal ultrasound to assess the cervical length and digital vaginal examination to assess the Bishop cervical scoring by separate investigators before induction of labour. Primary outcome measure To evaluate the association of the cervical length by transvaginal ultrasound scan and Bishop score in predicting successful induction of labour. Secondary outcome measure Variables associated with successful induction of labour and patients’ tolerability and acceptance for transvaginal ultrasound scan of cervix. Results There was no statistically significant difference among the vaginal and Caesarean delivery groups in terms of mean maternal age, height, weight, body mass index, ethnicity and gestational age at induction. Vaginal delivery occurred in 207 women (70.4%) and 87 women (29.6%) delivered via Caesarean section. There was a high degree of correlation between the cervical length and Bishop score (r-value 0.745; p <0.001). Sonographic assessment of cervical length demonstrated a comparable accuracy in comparison to Bishop score. Analysis using ROC curves noted an optimal cut-off value of ≤27mm for cervical length and Bishop score of ≥ 4, with a sensitivity of 69.1% vs 67%, specificity 60.9% vs 55%, and area under the curves (AUCs) of 0.672 and 0.643 respectively (p <0.001). Multivariate logistic regression analysis demonstrated that parity (OR 2.70), cervical length (OR 0.925), Bishop score (OR 1.272) and presence of funnelling (OR 3.292) were highly significant as independent predictors of success labour induction. Women also expressed significantly less discomfort with transvaginal ultrasound compared with digital vaginal examination. Conclusion Sonographic assessment of cervical measurement predicts the success of induction of labour with similar diagnostic accuracy with conventional Bishop score.


Download File

Full text not available from this repository.

Additional Metadata

Item Type: Article
Divisions: Faculty of Medicine and Health Science
DOI Number: https://doi.org/10.1371/journal.pone.0262387
Publisher: Public Library of Science
Keywords: Bishop's cervical score; Induction of labor; Pre-induction assessment; Term pregnancies; Transvaginal cervical length assessment; Good health and well-being
Depositing User: Mr. Mohamad Syahrul Nizam Md Ishak
Date Deposited: 30 Jun 2024 14:56
Last Modified: 30 Jun 2024 14:56
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.1371/journal.pone.0262387
URI: http://psasir.upm.edu.my/id/eprint/102848
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item