UPM Institutional Repository

Local diagnostic reference levels for full-field digital mammography and digital breast tomosynthesis in a tertiary hospital in Malaysia


Citation

Mohd Norsuddin, Norhashimah and Segar, Sharveeni and Ravintaran, Rathieswari and Mohd Zain, Norhayati and Abdul Karim, Muhammad Khalis (2022) Local diagnostic reference levels for full-field digital mammography and digital breast tomosynthesis in a tertiary hospital in Malaysia. Healthcare, 10 (10). art. no. 1917. pp. 1-16. ISSN 2227-9032

Abstract

A set of national diagnostic reference levels (DRLs) was established in Malaysia for a range of breast thicknesses in 2013, but no updates for full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT). Due to the increasing number of DBTs used and concern over radiation exposure, this study aimed to explore and establish local diagnostic reference levels for FFDM and DBT in Malaysia health facilities at different compressed breast thickness (CBT) ranges. The CBT, kilovoltage peak (kVp), Entrance surface dose (ESD), and average glandular dose (AGD) were retrospectively extracted from the mammography Digital Imaging and Communications in Medicine (DICOM) header. The 75th and 95th percentile values were obtained for the AGD distribution of each mammography projection for three sets of CBT range. The difference in AGD values between FFDM and DBT at three CBT ranges was determined. The DRLs for FFDM were 1.13 mGy, 1.52 mGy, and 2.87 mGy, while DBT were 1.18 mGy, 1.88 mGy, and 2.78 mGy at CBT ranges of 20–39 mm, 40–59 mm, and 60–99 mm, respectively. The AGD of DBT was significantly higher than FFDM for both mammographic views (p < 0.005). All three CBT groups showed a significant difference in AGD values for FFDM and DBT (p < 0.005). The local DRLs from this study were lower than the national DRLs, with the AGD of FFDM significantly lower than DBT.


Download File

Full text not available from this repository.
Official URL or Download Paper: https://www.mdpi.com/2227-9032/10/10/1917

Additional Metadata

Item Type: Article
Divisions: Faculty of Science
DOI Number: https://doi.org/10.3390/healthcare10101917
Publisher: MDPI AG
Keywords: Digital breast tomosynthesis; Full-field digital mammography; Diagnostic reference level; Average glandular dose; Compressed breast thickness
Depositing User: Ms. Che Wa Zakaria
Date Deposited: 08 Jun 2023 02:19
Last Modified: 08 Jun 2023 02:19
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.3390/healthcare10101917
URI: http://psasir.upm.edu.my/id/eprint/102103
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item