Dosimetric characteristics of fabricated germanium doped optical fibres for a postal audit of therapy electron beams


Citation

Abdullah, N. and Bradley, D. A. and Nisbet, A. and Kamarul Zaman, Z. and Deraman, S. S. and Mohd Noor, N. (2022) Dosimetric characteristics of fabricated germanium doped optical fibres for a postal audit of therapy electron beams. Radiation Physics and Chemistry, 200. art. no. 110346. pp. 1-7. ISSN 0969-806X

Abstract

The dosimetric characteristics of germanium (Ge) doped optical fibres are investigated as a potential dosimetric alternative for electron beam therapy postal audits. The dosimetric characteristics of 6 mol% Ge-doped optical fibres fabricated as cylindrical fibres (CF) and flat fibres (FF) are established in terms of signal fading, linearity of dose-response, beam energy- and dose rate dependence. Pilot electron beam therapy audit study irradiations are made with a linear accelerator located at the Royal Surrey County Hospital, applying International Atomic Energy Agency (IAEA) standard irradiation procedures for reference and non-reference conditions. Results for the CF and FF show fading of 26% and 20% respectively at 120 days post-irradiation. For a 6 MeV electron beam the dose-response is observed to be linear over the dose range 1–3 Gy, the least determination coefficient, R2, being 0.985. The results of the electron beam therapy audit are within the tolerance limit of 5% recommended by the International Commission on Radiation Units and Measurements (ICRU) Report No. 24, with a maximum deviation of 4% for FF at a 6 MeV electron beam under non-reference conditions. In conclusion, the fabricated Ge-doped optical fibres are seen to offer suitability for use as an alternative dosimeter to TLD-100 in electron beam therapy postal audit.


Download File

Full text not available from this repository.

Additional Metadata

Item Type: Article
Divisions: Faculty of Medicine and Health Science
Hospital Pengajar UPM
DOI Number: https://doi.org/10.1016/j.radphyschem.2022.110346
Publisher: Elsevier
Keywords: Fabricated Ge-Doped optical fibres; Electron beam therapy audit; Reference and non-reference conditions
Depositing User: Ms. Nur Faseha Mohd Kadim
Date Deposited: 12 Jul 2023 08:33
Last Modified: 12 Jul 2023 08:33
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.1016/j.radphyschem.2022.110346
URI: http://psasir.upm.edu.my/id/eprint/101008
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item