UPM Institutional Repository

Absolute reliability and concurrent validity of the modified goniometric platform for measuring trunk rotation in the sitting position


Citation

Gao, Jianhong and Thung, Jin Seng and Wei, Shanshan and Pavlu, Dagmar and Chee, Chen Soon and Ramasamy, Yuvaraj and Mohd Ali, Azril Syazwan and Mat Yatim, Rosnah (2022) Absolute reliability and concurrent validity of the modified goniometric platform for measuring trunk rotation in the sitting position. Applied Sciences, 12 (17). art. no. 8891. pp. 1-9. ISSN 2076-3417

Abstract

The modified goniometric platform (MGP) is a novel instrument used to measure trunk rotation while sitting. A lack of reliable and valid evidence has been reported to measure trunk rotation using MGP. Therefore, this study was aimed to investigate the intra- and inter-rater reliabilities and validity of the MGP for measuring trunk rotation while sitting. Methods: Seventeen participants performed right trunk rotation followed by left trunk rotation (three repetitions for each trial) and two random measurements at 40-minute intervals. Inter-rater and intra-rater reliabilities were calculated using intraclass correlation coefficients (ICCs). Validity was assessed using the Pearson correlation coefficient (r). Results: The test and re-test inter-rater reliabilities for right trunk rotation were 0.990 and 0.986, respectively, and those for left trunk rotation were 0.989 and 0.978, respectively. The intra-rater reliabilities for right trunk rotation were 0.949 and 0.954, respectively, and those for left trunk rotation were 0.944 and 0.946, respectively. The right and left trunk rotation validities were 0.986 and 0.981, respectively. Conclusion: MGP is reliable and valid for measuring right and left trunk rotations while sitting.


Download File

Full text not available from this repository.
Official URL or Download Paper: https://www.mdpi.com/2076-3417/12/17/8891

Additional Metadata

Item Type: Article
Divisions: Faculty of Educational Studies
DOI Number: https://doi.org/10.3390/app12178891
Publisher: Multidisciplinary Digital Publishing Institute
Keywords: Modified goniometric platform 2D video analysis; Trunk rotation
Depositing User: Ms. Nur Faseha Mohd Kadim
Date Deposited: 01 Aug 2024 07:40
Last Modified: 01 Aug 2024 07:40
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.3390/app12178891
URI: http://psasir.upm.edu.my/id/eprint/100073
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item