UPM Institutional Repository

Design sensitive model reference controller with application to medical technology


Citation

Bahrami, Rouhollah and Soltani, Samira and Rashidi Bod, Hossein and Jowkar, Somayeh and Sahamijoo, Amirzubir and Taghizadegan, Ali and Sulaiman, Nasri. B (2016) Design sensitive model reference controller with application to medical technology. International Journal of Hybrid Information Technology, 9 (7). pp. 249-268. ISSN 1738-9968

Abstract

The past two decades have seen the incorporation of robotics into medical applications. From a manufacturing perspective, robots have been used in pharmaceuticals, preparing medications. But on more novel levels, robots have been used in service roles, surgery, and prosthetics. The capability of high-precision operation in manufacturing settings gave the medical industry high hopes that robots could be used to assist in surgery. Not only are robots capable of much higher precision than a human, they are not susceptible to human factors, such as trembling and sneezing, that are undesirable in the surgery room. Another advantage to robots in medicine is the ability to perform surgery with very small incisions, which results in minimal scar tissue, and dramatically reduced recovery times. The popularity of these minimally invasive surgical (MIS) procedures has enabled the incorporation of robots in surgeries. In this paper, model reference computed torque controller is recommended for four degrees of freedom serial links robot manipulator, which modeled in SIMSCAPE. To design stable controller conventional computed torque controller is recommended. It is a nonlinear, stable, and reliable controller. The proposed approach effectively combines of design methods from nonlinear controller, and linear Proportional-Derivative (PD) control to improve the performance and stability. This paper has two important objectives: a) study on modeling of 4 degrees of freedom (DOF) based on Simscape software and b) design PD model reference computed torque controller to improve the sensitivity of surgical robot manipulator.


Download File

[img]
Preview
PDF (Abstract)
Design sensitive model reference controller with application to medical technology.pdf

Download (85kB) | Preview

Additional Metadata

Item Type: Article
Divisions: Faculty of Engineering
DOI Number: https://doi.org/10.14257/ijhit .2016 .9.7.23
Publisher: Science & Engineering Research Support Society (SERSC)
Keywords: Surgical robots; Four degrees of freedom; Model reference computed torque controller
Depositing User: Mohd Hafiz Che Mahasan
Date Deposited: 14 Sep 2017 09:57
Last Modified: 14 Sep 2017 09:57
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.14257/ijhit .2016 .9.7.23
URI: http://psasir.upm.edu.my/id/eprint/55456
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item