Citation
Wan Ahmad, Wan Fatinhamamah and Thomas, David W. P. and Christopoulos, Christos and Mohd Sharim, Khairul Ariffin and Jasni, Jasronita and Ab Kadir, Mohd Zainal Abidin and Hizam, Hashim
(2008)
Transient responses due to various burial depths on a single long horizontal ground conductor.
In: 2008 IEEE 2nd International Power and Energy Conference (PECon 2008), 1-3 Dec. 2008, Johor Bahru, Malaysia. (pp. 372-377).
Abstract
The purpose for this paper is to determine the effective burial depth for a single long horizontal ground conductor which is part of a lightning protection system. In this study, transient responses behaviours of the ground conductor towards various burial depths with lightning excitation are presented. The simulation is done in the time domain using TLM which is found to be the ideally suited numerical method due to its many advantages. The excitation voltage is injected at one end of the ground conductor, represented by a derivative Gaussian pure injection voltage source. Results are presented regarding various burial depths at each node of the ground conductor and a good agreement with an IEEE standard is shown.
Download File
Preview |
|
PDF (Abstract)
Transient responses due to various burial depths on a single long horizontal ground conductor.pdf
Download (34kB)
| Preview
|
|
Additional Metadata
Actions (login required)
|
View Item |