Monte Carlo design of optimal wire mesh collimator for breast tumor imaging process.


Citation

Mohd Saad, Wira Hidayat and Roslan, Ros Ernida and Mahdi, Mohd Adzir and Choong, Woon Seng and Saion, Elias and Saripan, M. Iqbal (2011) Monte Carlo design of optimal wire mesh collimator for breast tumor imaging process. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 648 (1). pp. 254-260. ISSN 0168-9002

Abstract

This paper presents the modeling of breast tumor imaging process using wire mesh collimator gamma camera. Previous studies showed that the wire mesh collimator has a potential to improve the sensitivity of the tumor detection. In this paper, we extend our research significantly, to find an optimal configuration of the wire mesh collimator specifically for semi-compressed breast tumor detection, by looking into four major factors: weight, sensitivity, spatial resolution and tumor contrast. The numbers of layers in the wire mesh collimator is varied to optimize the collimator design. The statistical variations of the results are studied by simulating multiple realizations for each experiment using different starting random numbers. All the simulation environments are modeled using Monte Carlo N-Particle Code (MCNP). The quality of the detection is measured directly by comparing the sensitivity, spatial resolution and tumor contrast of the images produced by the wire mesh collimator and benchmarked that with a standard multihole collimator. The proposed optimal configuration of the wire mesh collimator is optimized by selecting the number of layers in wire mesh collimator, where the tumor contrast shows a relatively comparable value to the multihole collimator, when it is tested with uniformly semi-compressed breast phantom. The wire mesh collimator showed higher number of sensitivity because of its loose arrangement while the spatial resolution of wire mesh collimator does not shows much different compared to the multihole collimator. With a relatively good tumor contrast and spatial resolution, and increased in sensitivity, a new proposed wire mesh collimator gives a significant improvement in the wire mesh collimator design for breast cancer imaging process. The proposed collimator configuration is reduced to 44.09% from the total multihole collimator weight.


Download File

[img]
Preview
PDF (Abstract)
Monte Carlo design of optimal wire mesh collimator for breast tumor imaging process.pdf

Download (84kB) | Preview

Additional Metadata

Item Type: Article
Divisions: Faculty of Medicine and Health Science
Faculty of Science
DOI Number: https://doi.org/10.1016/j.nima.2011.05.064
Publisher: Elsevier
Keywords: Breast tumor; Gamma camera; MCNP; Monte Carlo; Wire mesh collimator.