Monitoring peroxide value in oxidized emulsions by Fourier transform infrared spectroscopy

Ibrahim, Nor Hayati and Che Man, Yaakob and Tan, Chin Ping and Idris, Nor Aini (2005) Monitoring peroxide value in oxidized emulsions by Fourier transform infrared spectroscopy. European Journal of Lipid Science and Technology, 107 (12). pp. 886-895. ISSN 1438-7697

Full text not available from this repository.

Official URL: http://dx.doi.org/10.1002/ejlt.200500241

Abstract

Soybean oil (SBO) was blended with 10-40% palm kernel olein (PKO) to obtain SBO:PKO blends with different degrees of unsaturation. Oil-in-water (O/W) emulsions were then prepared with 70 wt-% of SBO or SBO:PKO blends and monitored for their chemical destabilization after an accelerated oxidation process up to 12 days at 60°C. The formation rate of hydroperoxides, as demonstrated by peroxide value (PV) evolution, throughout the oxidation period was relatively high for a fully SBO-based emulsion as compared to those with PKO incorporation. Fourier transform infrared (FTIR) spectroscopic method was also performed in parallel with PV determination, providing further information on structural changes of the functional groups due to lipid oxidation in the emulsions. By using a partial least square chemometric method, a developed calibration model that was based on the spectral region between 1800 and 1480 cm-1 was shown to be able to predict the PV in oxidized emulsions over the range of 4-45 meq/kg. With a 'leave-one-out' cross-validation optimization procedure, the calibration model provides a good coefficient of determination of 0.98 and a root mean standard error of cross-validation of 2.09. In general, FTIR spectroscopy is a suitable technique to monitor PV in oxidized emulsions. © 2005 Wiley-VCH Verlag GmbH & Co. KGaA.

Item Type:Article
Keyword:Emulsion destabilization; FTIR; Lipid oxidation; Palm kernel olein; Peroxide value
Subject:Emulsions
Subject:Fourier transform infrared spectroscopy
Subject:Peroxides
Faculty or Institute:Faculty of Food Science and Technology
DOI Number:10.1002/ejlt.200500241
Altmetrics:http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.1002/ejlt.200500241
ID Code:18342
Deposited By: Azwana Abdul Rahman
Deposited On:27 Oct 2011 12:46
Last Modified:27 Oct 2011 12:46

Repository Staff Only: item control page

Document Download Statistics

This item has been downloaded for since 27 Oct 2011 12:46.

View statistics for "Monitoring peroxide value in oxidized emulsions by Fourier transform infrared spectroscopy"


Universiti Putra Malaysia Institutional Repository

Universiti Putra Malaysia Institutional Repository is an on-line digital archive that serves as a central collection and storage of scientific information and research at the Universiti Putra Malaysia.

Currently, the collections deposited in the IR consists of Master and PhD theses, Master and PhD Project Report, Journal Articles, Journal Bulletins, Conference Papers, UPM News, Newspaper Cuttings, Patents and Inaugural Lectures.

As the policy of the university does not permit users to view thesis in full text, access is only given to the first 24 pages only.