Keyword Search:

Computed and conventional chest radiography: A comparison of image quality and radiation dose

Ramli, Khadijah and Abdullah, Basri Johan Jeet and Ng, Kwan Hoong and Mahmud, Rozi and Hussain, Amir Fuad (2005) Computed and conventional chest radiography: A comparison of image quality and radiation dose. Australasian Radiology, 49 (6). pp. 460-466. ISSN 0004-8461

Full text not available from this repository.

Official URL: http://dx.doi.org/10.1111/j.1440-1673.2005.01497.x

Abstract

The aim of this study was to compare the image quality and entrance skin dose (ESD) for film-screen and computed chest radiography. Analysis of the image quality and dose on chest radiography was carried out on a conventional X-ray unit using film-screen, storage phosphor plates and selenium drum direct chest radiography. For each receptor, ESD was measured in 60 patients using thermoluminescent dosemeters. Images were printed on 35 × 43 cm films. Image quality was assessed subjectively by evaluation of anatomic features and estimation of the image quality, following the guidelines established by the protocols of the Commission of the European Communities. There was no statistically significant difference noted between the computed and conventional images (Wilcoxon rank sum test, P > 0.05). Imaging of the mediastinum and peripheral lung structures were better visualized with the storage phosphor and selenium drum technique than with the film-screen combination. The patients' mean ESD for chest radiography using the storage phosphor, film-screen combination and selenium drum was 0.20, 0.20 and 0.25 mGy, respectively, with no statistically significant difference with P > 0.05 (χ2 tests). © 2005 Royal Australian and New Zealand College of Radiologists

Item Type:Article
Keyword:Commission of the European Communities; Film-screen; Selenium drum; Storage phosphor
Subject:Chest - Radiography
Subject:Radiography - Image quality
Subject:Radiation dosimetry
Faculty or Institute:Faculty of Medicine and Health Science
Publisher:Royal Australian and New Zealand College of Radiologists
DOI Number:10.1111/j.1440-1673.2005.01497.x
Altmetrics:http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.1111/j.1440-1673.2005.01497.x
ID Code:18327
Deposited By: Azwana Abdul Rahman
Deposited On:26 Oct 2011 23:04
Last Modified:26 Oct 2011 23:04

Repository Staff Only: Edit item detail

Document Download Statistics

This item has been downloaded for since 26 Oct 2011 23:04.

View statistics for "Computed and conventional chest radiography: A comparison of image quality and radiation dose"