Power Factor Correction Using Single Stage Discontinuous Conduction Mode Booster Rectifier

Athab, Hussain Sabri (2003) Power Factor Correction Using Single Stage Discontinuous Conduction Mode Booster Rectifier. Masters thesis, Universiti Putra Malaysia.

[img] PDF
951Kb

Abstract

A single stage three-phase power factor correction circuit using a boost input current shaper has been described in both simulation and experimental work. To reduce the cost and avoid complexity the boost dc-to-dc converter is operated in discontinuous conduction mode using only one active switch. A low cost harmonic injection method for single switch three-phase DCM boost rectifiers has been simulated and tested. In this method, a periodic voltage which is proportional to the inverted ac component of the rectified three-phase line-to-line input voltage is injected in the control circuit to vary the duty cycle of the rectifier switch within a line cycle, so that the fifth-order harmonics of the input current is reduced to meet THD<10% requirement.The analysis of the injected signal and modified harmonic currents of the rectifier has been presented and verified on a laboratory prototype. Based on the equivalent multimodel an average small signal model of the boost power stage is developed and verified by simulation. The variations of the small signal model against load are demonstrated, and the compensator designed for constant switching frequency PWM is discussed. The simulated results show that at light load, the dominant pole of the control-to-output transfer function approaches the origin and causes more phase delay, complicating the control design circuit. To avoid the no load case and simplify the control design, a dummy is added. The single stage three-phase boost power factor correction with improved input current distortion has been simulated using OrCad release 9.1 software. The results show there is an agreement between the simulation and experimental work.

Item Type:Thesis (Masters)
Subject:Rectifier
Subject:Cost - Accounting
Chairman Supervisor:Sinan Mahmoud Abdullah, PhD
Call Number:FK 2003 53
Faculty or Institute:Faculty of Engineering
ID Code:12214
Deposited By: Mohd Nezeri Mohamad
Deposited On:14 Jul 2011 04:35
Last Modified:06 Sep 2011 07:24

Repository Staff Only: item control page

Document Download Statistics

This item has been downloaded for since 14 Jul 2011 04:35.

View statistics for "Power Factor Correction Using Single Stage Discontinuous Conduction Mode Booster Rectifier "


Universiti Putra Malaysia Institutional Repository

Universiti Putra Malaysia Institutional Repository is an on-line digital archive that serves as a central collection and storage of scientific information and research at the Universiti Putra Malaysia.

Currently, the collections deposited in the IR consists of Master and PhD theses, Master and PhD Project Report, Journal Articles, Journal Bulletins, Conference Papers, UPM News, Newspaper Cuttings, Patents and Inaugural Lectures.

As the policy of the university does not permit users to view thesis in full text, access is only given to the first 24 pages only.