Roslan, R. E. and Mohd Saad, Wira Hidayat and Saripan, M. Iqbal and Hashim, Sharifah and Choong, W. S. (2010) The performance of a wire mesh collimator SPECT camera for different breast volumes in prone position. Nuclear Instruments and Methods in Physics Research Section A, 619 (1-3). pp. 385-387. ISSN 0168-9002

Full text not available from this repository.

Abstract

The multihole collimator is the most commonly used collimator in conventional SPECT cameras for general purpose imaging. However, there are some limitations with this collimator, which includes the lack of sensitivity as a trade-off for obtaining better spatial resolution. This paper looks at the performance of a wire mesh collimator that was introduced recently in order to improve the ability of SPECT cameras in mapping breast cancer cells, utilizing the Technetium-99 m 140 keV radiotracer. In this work, various volumes of breast are modelled and simulated using Monte Carlo N-Particle (MCNP5) code, derived based on the real cup sizes and volumes in prone position. The size of tumour is 1 cm in diameter with tumour to background ratios (TBRs) ranging between TBR from 1:1 to TBR 20:1, and located 2 cm inside breast skin. The results show that wire mesh collimator 1 (WM-1) has the highest sensitivity and signal to noise ratio (SNR) in comparison with wire mesh collimator 2 (WM-2) and the multihole collimator (MHC). This indicates the potential of using a wire mesh collimator for early mapping of breast cancer cells.

Item Type:Article
Keyword:Wire-mesh collimator, Multihole collimator, SPECT camera, TBR, SNR, Breast, Prone position
Faculty or Institute:Faculty of Engineering
DOI Number:10.1016/j.nima.2009.11.005
Altmetrics:http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.1016/j.nima.2009.11.005
ID Code:11644
Deposited By: kmportal
Deposited On:08 Apr 2011 09:36
Last Modified:08 Apr 2011 09:44

Repository Staff Only: item control page

Document Download Statistics

This item has been downloaded for since 08 Apr 2011 09:36.

View statistics for "The performance of a wire mesh collimator SPECT camera for different breast volumes in prone position"


Universiti Putra Malaysia Institutional Repository

Universiti Putra Malaysia Institutional Repository is an on-line digital archive that serves as a central collection and storage of scientific information and research at the Universiti Putra Malaysia.

Currently, the collections deposited in the IR consists of Master and PhD theses, Master and PhD Project Report, Journal Articles, Journal Bulletins, Conference Papers, UPM News, Newspaper Cuttings, Patents and Inaugural Lectures.

As the policy of the university does not permit users to view thesis in full text, access is only given to the first 24 pages only.