Reliability, technical error of measurements and validity of instruments for nutritional status assessment of adults in Malaysia

Appannah, Geeta and Haniff, Jamaiyah and Mohammad Nor, Noor Safiza and Wong, N. F. and Kee, Chee Cheong and Zainuddin, Ahmad Ali and Shahar, Suzana and Rasat, Rahmah and Khor, Geok Lin and Abd Talib, Ruzita and Chen, Won Sun and M., Rajaah and Yusoff, Ahmad Faudzi (2008) Reliability, technical error of measurements and validity of instruments for nutritional status assessment of adults in Malaysia. Malaysian Journal of Nutrition, 14 (2). S25-S26. ISSN 1394-035X

Full text not available from this repository.

Official URL: http://www.nutriweb.org.my/publications/mjn0014_2/...

Abstract

The Third National Health & Morbidity Survey, Malaysia 2006 included nutritional status assessment of children. This study was to assess inter-and intra-examiner reliability, the technical error of measurement (TEM) and the validity of instruments for measuring weight, length and waist circumference. A convenience sample of 130 adults working in a selected office setting who fit the inclusion and exclusion criteria participated in the study. Two public health nurses, trained to follow a standard protocol, obtained the measurements. Weight was measured using Tanita digital weighing scale, 318, Japan (0.1 kg) and Seca Beam Scale, Germany (0.01 kg) weighing machines. Height was measured using Seca Bodymeter 206 Germany (0.1cm) and Stadiometer, Germany (0.1cm). Waist circumference was measured using Seca circumference tape, 206, Germany (0.1 cm). By comparison the inter-examiner reliability in descending order would be weight, height and lastly waist circumference. The intra-examiner reliability in descending order would be weight and height followed by waist circumference. Height measurement on average using test instrument reported that it was recording 0.4 cm higher than the reference instrument with upper limit and lower limit at 2.5 and 1.6 cm respectively. The technical error of measurement and coefficient of variation of weight and height for both inter-examiner and intra-examiner measurements are all within acceptable limit (below 5%). The findings of this study supports that weight, height and waist circumference measured in adults 30 years and above using Tanita digital weighing scale, 318, Japan (0.1 kg), Seca Bodymeter 206 Germany (0.1cm) and Seca circumference tape, 206, Germany (0.1 cm) are reliable and valid to be used in a community survey. Limiting the number of examiners especially for waist circumference measurements would yield higher degree of reliability and validity.

Item Type:Article
Faculty or Institute:Faculty of Medicine and Health Science
Publisher:Nutrition Society of Malaysia
ID Code:6844
Deposited By: Anas Yahaya
Deposited On:21 May 2010 03:42
Last Modified:28 Jul 2010 08:27

Repository Staff Only: item control page


Universiti Putra Malaysia Institutional Repository

Universiti Putra Malaysia Institutional Repository is an on-line digital archive that serves as a central collection and storage of scientific information and research at the Universiti Putra Malaysia.

Currently, the collections deposited in the IR consists of Master and PhD theses, Master and PhD Project Report, Journal Articles, Journal Bulletins, Conference Papers, UPM News, Newspaper Cuttings, Patents and Inaugural Lectures.

As the policy of the university does not permit users to view thesis in full text, access is only given to the first 24 pages only.