UPM Institutional Repository

Determination of iodine value of palm olein mixtures using differential scanning calorimetry


Citation

Chu, Boon Seang and Tan, Chin Ping and Mohd Ghazali, Hasanah and Lai, Oi Ming (2002) Determination of iodine value of palm olein mixtures using differential scanning calorimetry. European Journal of Lipid Science and Technology, 104 (8). pp. 472-482. ISSN 1438-7697; ESSN: 1438-9312

Abstract

Differential scanning calorimetry (DSC) was used to determine the iodine value (IV) of various palm olein (PoO) mixtures. Eight different PoO mixtures, namely, PoO:PKO, PoO:CoO, PoO:PS, PoO:PO, PoO:CaO, PoO:OeO, PoO:CnO and PoO:SFO were prepared at different ratios (w/w) to give various IV (PKO represents palm kernel olein; CoO, coconut oil; PS, palm stearin; PO, palm oil; CaO, canola oil; OeO, olive oil; CnO, corn oil; and SFO, sunflower oil). Each sample was then scanned from 80 to - 100 °C at -5 °C/min using a DSC. All the mixtures showed two exothermic peaks in their cooling thermograms, except PoO:SFO mixtures which showed three peaks. Results of stepwise multiple linear regression (SMLR) analysis showed that five independent variables extracted from each of these peaks, namely, on-set temperature, off-set temperature, peak temperature, peak height and peak enthalpy could predict well the IV of each mixture. The calibration models developed showed appreciable effectiveness, re-producibility and accuracy, and specificity towards the calibration data set. A shared calibration model for each group of PoO mixtures i.e. high-lauric (PoO:PKO and PoO:CoO), high-palmitic (PoO:PS and PoO:PO) and high-oleic (PoO:CaO and PoO:OeO) mixtures was also developed. SMLR analysis showed that the shared models were also capable in predicting IV of the PoO mixtures, even though the coefficient of determination, R2, was slightly lower than that of their individual models. The shared calibration models also had good reproducibility and accuracy when compared with the standard chemical method. In conclusion, DSC provides an effective method in determining IV for routine analysis in the industries, whereby one single model could be calibrated for the use of all oil and fat products that have similar chemical compositions such as high-lauric, high-palmitic or high-oleic mixtures in the industry.


Download File

[img]
Preview
PDF (Abstract)
Determination of iodine value of palm olein mixtures using differential scanning calorimetry.pdf

Download (37kB) | Preview

Additional Metadata

Item Type: Article
Divisions: Faculty of Food Science and Biotechnology
DOI Number: https://doi.org/10.1002/1438-9312(200208)104:8<472::AID-EJLT472>3.0.CO;2-U
Publisher: Wiley-VCH Verlag GmbH & Co. KGaA
Keywords: Calibration model; Differential scanning calorimetry; Iodine value; Palm olein mixtures
Depositing User: Nabilah Mustapa
Date Deposited: 23 Jan 2018 05:43
Last Modified: 23 Jan 2018 05:43
Altmetrics: http://www.altmetric.com/details.php?domain=psasir.upm.edu.my&doi=10.1002/1438-9312(200208)104:8<472::AID-EJLT472>3.0.CO;2-U
URI: http://psasir.upm.edu.my/id/eprint/58567
Statistic Details: View Download Statistic

Actions (login required)

View Item View Item